            INSTALLATION AND STARTUP


            Chapter 10 Initial Startup



            Startup Procedure

               Foaming Components Setup

               1)  Open Triple Foam water valves completely (located in the Carriage). Force on TF CHEM and
                   TF WTR/AIR. Set chemical pumps to supplier’s recommendations. Increase Tri-Foam air
                   pressure (in passenger side pod) to about 10PSI. Continue to increase until air blows past
                   the chemical and then reduce air slightly. This can be done by sound. Adjust the 3 Tri-Foam
                   gate  valves inside the exit water manifold cover to achieve the desired “wetness”.  NOTE:
                   Yellow typically requires more chemical. Tilt Tri-Foam Pods to get the best spray pattern
                   on average vehicles. Next turn soap back on and adjust spray angle for soap pods. Reset all
                   forces.

                       Pulsatron Pump Style Shown




                                                                Tri-Foam
                                                          Adjustment Screw
                       Tri-Foam                                                           Tri-Foam Pod
                     Gate Valves


                                                          Single Foam Pod






               Setting Cylinder Flow Controls
               1)  Set cylinder flow controls as stated below.
                          •   Exit Arm Side: Green Ring on flow control
                          •   Entrance Pivot Side: Blue Ring
                          •   Top Wheel: Open 1/4 Turn (to green ring)
                                  Ring Color   Turns open
                                   Green         1
                                   Orange        2
                                    Blue         3
                                   Silver        4
                                    Red        5 (full)

                   Note:  Never lower top wheel when entrance water manifold cover is open.

               2)  Close all covers (entrance and exit water covers and both pod covers).