INSTALLATION AND STARTUP
Chapter 4 Frame and Carriage Assembly
Passenger Side Boom Install
Optional HydroBlade®/ Wheel Cleaner Manifold Accessories
Assuming your system needs to have the components shown below moved from a driver side
equipment room to a passenger side equipment room; follow the following instructions to
accommodate this configuration.
Lexair™ Distribution Manifold
1) Locate the Lexair™ Manifold assembly atop of the carriage on the passenger side.
Disconnect both ends of the 2 hydraulic hoses that are connected from the
Lexair™ Manifold to the Center Feed Manifolds.
Note: The inner most hose goes to the HydroBlade® center feed
manifold which is the upper and the outer most hose goes to the
Wheel Cleaner center feed manifold which is the lower.
2) Remove the four 5/16-18 fasteners, flat washers, Nylock nuts, and the two clamps Lexair™ Manifold
that are holding the manifold assembly to the carriage c-channel as shown below.
3) Move the manifold assembly to a workbench that has a vice on it so that you can rotate the fittings around to
their appropriate orientation. Once at the workbench, loosen the brass swivel fittings that hold the Lexair™
Valves in place. Remove the Lexair™ Valves and set them off to the side.
4) On one end of the manifold there is the Main Feed Connection. Turn the top elbow so that it faces the
entrance side of the machine and is angled toward the outside of the carriage as shown below.
Note: Make sure that all of the other fittings stay tight!
Main Feed Connection
Before After