Page 28 - Pivoting Wheel Stinger™ Signature® Series
P. 28

PIVOTING WHEEL STINGER Signature Series





            Maintenance



            Routine Procedures
               Triple and Single Pods
                •   Check spray nozzles
                •   Run a test wash to begin each business day
                •   Inspect all air-lines making sure they are not making contact with sharp objects or in the path of vehicles

            Trouble Shooting


                   Problem                  Cause                             Solution
               No chemical        •   Clogged foot valve on suction line   •   Clean or replace foot valve

                                  •   Empty storage tank      •   Fill storage tank
                                  •   Chemical pump has lost prime   •   Prime chemical pump
                                  •   Solenoid valve not energized   •   Check for proper operating voltage
               Pulsating or weak   •   Dirt in solenoid valve   •   Disassemble and clean solenoid valve
               spray
                                  •   Kink in hose            •   Remove any kinks from hose

                                  •   Inadequate water pressure   •   Open water valve to fullest
                                  •   Blocked screen          •   Call Distributor for advice on installing booster pump
                                  •   Spray holes clogged     •   Remove from Pod and blow the screen to remove any
                                                                  film
                                  •   Loose or bad fittings
                                                              •   Disable  the Pod and clean with thin wire and blow
                                  •   In-Line Check Valve for     through each port
                                     water/chemical facing wrong
                                     direction                •   Check all fittings on the complete system to assure
                                                                  that they are tight and do not leak
                                                              •   Make sure the arrow on the Check  Valve  is  facing
                                                                  towards the black Feed-Block of the Pod






























             26        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (810) 349-7010 * Fax (810) 380-9681          1MANUL587
   23   24   25   26   27   28   29   30   31   32   33