Page 28 - SideWinder®
P. 28
®
SideWinder
Installation
Utilities
Pneumatic Connections: Air Panels to Cylinders
1) Mount the four Air Regulation Panels in the equipment room and route a 1/4” poly-flow
airline from the Main Air Supply to the air panels and connect to the location shown below.
Retract Regulator Extend Regulator Manual Over-ride
20 to 30 PSI 20 to 30 PSI
SIDEWINDER
Main Air Supply Retract Valve
90-PSI minimum
120-PSI maximum
2) Determine and label two Air Panels for the driver side SideWinder® and two for the
passenger side SideWinder®. All labels for the Air Panels are to be field supplied.
3) Use 1/4” field supplied black airlines for extending the Cylinders and 1/4” field supplied gray
airlines for retracting the Cylinders on the SideWinders®.
4) Measure the distance from the Air Panels to the Utility Manifold on the driver side and
passenger side SideWinders®.
5) Cut four 1/4” black airlines and four 1/4” gray airlines to the measured lengths.
6) Starting with the two Driver Side Air Panels connect a black airline to the Extend Regulator
and a gray airline to the Retract Regulator on each Air Panel.
DS Extend Regulator
Air Panel for Driver Side
Upper Cylinder
1/4” Black Airline to
Extend Driver Side
Upper Cylinder
1/4” Gray Airline to
Retract Driver Side
Upper Cylinder
Helpful Hint
Retract Regulator
Labels for the Air Panel Regulators are
not provided, however, they are
recommended for clarity. Air Panel for Driver Side
Lower Cylinder
1/4” Black Airline to
Extend Driver Side
Lower Cylinder
1/4” Gray Airline to
Retract Driver Side
Lower Cylinder
26 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL955