Connecting the Chemical Delivery System to SideWinders®
8) Locate the Blue Hose and four (4) Clamps that were supplied with the SideWinder® assemblies.
This Hose will be used to connect the Utility Manifold to the Water Manifold on each
SideWinder®.
Blue Water Hose
½” Dia. 200PSI 5’ Length ½ Hose Clamps
9) Measure and cut the Blue Hose to the desired length; be sure to provide adequate slack in the
hose to allow for the full range of motion of the SideWinders®.
Note: It is recommended that the hydraulic lines be wrapped with spiral wrap for support to prevent
them from distorting and premature wear.
10) Then on each SideWinder® clamp the Hydraulic Hose to the hydraulic fitting on the Utility
Manifold and to the hydraulic fitting on the Water Manifold, as shown below.
Pivot Weldment
Water Manifold
Hydraulic Fitting
Hose Clamp
½” Blue Water Hose
Hose Clamp
Utility Manifold