Page 32 - SideWinder®
P. 32
®
SideWinder
Installation
Utilities
Electrical Connections: Motor
The driver side and passenger side SideWinders® each have a 1HP 3-Phase motor that comes
wired for either 208/230, 460 or 575 VAC which was specified when the equipment was ordered.
One of the stickers, shown below, will be applied to the Electrical Junction Boxes to specify which
VAC the SiderWinder® motors on the assemblies were wired for.
CAUTION: CAUTION: CAUTION:
FACTORY WIRED FACTORY WIRED FACTORY WIRED
208/230 VAC 460 VAC 575 VAC
On the SideWinders®, the motor wire has been routed from the motor through a sleeve on the Tie
Bar and into the Junction Box, where they are ready to be connected to the main power source.
Junction Box
Tie Bar Sleeve
Gearbox/Motor Motor Cable
Note: Be sure to follow local electrical codes when choosing wiring materials and when routing
electrical wires.
Connecting Motors to Main Power
1) Run the main power line out to SideWinders® and make the wire connections to the motor
wires inside the Junction Boxes.
Note: Make sure electrical box penetrations are made with an approved method for wet
conditions. A proper cord grip should be used and installed correctly and a drip loop on
incoming cables is recommended to avoid any water intrusion.
Note: The electrical connections are made with either heat shrink butt splices or dielectric grease
wire nuts.
2) When everything is wired properly, close and seal the Junction Boxes be cautious to not
crimp down on any of the wires.
3) Test to see if the SideWinders® are functioning properly by using the Controller to turn on
each of the SideWinders®.
30 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL955