               Electrical Connections: Motor

               The  driver  side  and  passenger  side  SideWinders®  each  have  a  1HP  3-Phase  motor  that  comes
               wired for either 208/230, 460 or 575 VAC which was specified when the equipment was ordered.
               One of the stickers, shown below, will be applied to the Electrical Junction Boxes to specify which
               VAC the SiderWinder® motors on the assemblies were wired for.


                        CAUTION:                       CAUTION:                        CAUTION:
                 FACTORY WIRED  FACTORY WIRED                                  FACTORY WIRED

                       208/230 VAC                      460 VAC                        575 VAC


               On the SideWinders®, the motor wire has been routed from the motor through a sleeve on the Tie
               Bar and into the Junction Box, where they are ready to be connected to the main power source.





                                                                                          Junction Box



                                                                     Tie Bar Sleeve










                  Gearbox/Motor   Motor Cable

                 Note:  Be  sure  to  follow  local  electrical  codes  when  choosing  wiring  materials  and  when  routing
                        electrical wires.

                   Connecting Motors to Main Power
                   1)  Run the main power line out to SideWinders® and make the wire connections to the motor
                       wires inside the Junction Boxes.

                      Note:  Make  sure  electrical  box  penetrations  are  made  with  an  approved  method  for  wet

                            conditions. A proper cord grip should be used and installed correctly and a drip loop on
                            incoming cables is recommended to avoid any water intrusion.

                      Note: The electrical connections are made with either heat shrink butt splices or dielectric grease
                            wire nuts.

                   2)  When everything  is  wired  properly, close and seal  the Junction Boxes be cautious to not
                       crimp down on any of the wires.
                   3)  Test to see if the SideWinders® are functioning properly by using the Controller to turn on
                       each of the SideWinders®.