Page 35 - SideWinder®
P. 35

®
                    SideWinder

                    Maintenance

                    Daily

                                Inspect  the  SideWinder®  Assemblies  overall;  for  damaged  or missing  foam  on  cleaning
                                hubs, loose bolts that may cause wobbling, and worn bearings.

                    Monthly
                                Inspect cleaning foam on all cleaning hubs for wear or damage, replace as needed.
                                Grease arm pivot bearings (4 per side) using marine grease.

                           Note:  Before GREASING and after GREASING wipe off all bearing seal surfaces and Zerks. Grease
                                  should only be applied until water is pushed out and bearings seals start to swell.
                           Note:  The bottom bearings are accessible to be wiped clean, however the upper bearings are not,
                                  access the top bearings by removing the bolt on top of the utility weldments.

                                Apply Fluid Film Rust and Corrosion Preventative spray liberally to all arm pivot bearings
                                (4 per side).
                                Apply  Moly  Grease  to  the  Universal  Joint  every  other  month  or  every  25,000  cars
                                whichever comes first.  Using a needle injector on a grease gun fill the boot 3/4 full with
                                grease. Compress and massage the outside of the boot to work the lubricant into the joint.


                    Troubleshooting

                             Problem                  Cause                             Solution
                       Cleaning Hubs not         Mechanical failure may      Check to see if bearings are seized up. If so,
                       spinning                   be possible              see replacement parts.
                                                 If using flow control,
                                                  make sure it is open. If      Check that the SideWinder® shaft keyway and
                                                  unsure, whether it is    coupler are intact.
                                                  working properly,
                                                  remove and try without
                                                  flow control
                       Cleaning Hubs will not      Faulty electrical signal      Check electrical signal
                       retract
                                                 Faulty MAC valve        Remove airline from ports 2 and 3 of 4-way
                                                                           valve. Jog toggle switch on controller on and
                                                                           off.  If air is not felt when switching from 2 and
                                                                           3, then valve is bad.  See replacement parts

                       Excessive vibration       Floor lags may be loose      Make sure that the SideWinder® is tightly
                                                                           lagged to floor
                                                 Bearing may need        Check for play in the pivot arm bearings, if
                                                  replacing                sloppiness is evident, bearings will have to be
                                                                           replaced. See replacement parts












                       1MANUL955       Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681      33