                      Chapter 6 Faults and Alarms


                      Alarm Summaries

                          CHECK THERMOSTAT
                               This alarm occurs when the heater output has been blocked from staying on because it has been on for longer
                               than 45 minutes.

                          CHECK ARM PROX
                               This alarm occurs when the arm is slowed down because its position remains at ZERO for too long after the
                               arm has started moving. The position will increase from ZERO with any change of input status from the Arm
                               Encoder Prox.

                          BREAKAWAY FROM JAM PREVENTION
                               This alarm occurs if the machine has gone into the Breakaway condition because an Arm Jam was about to
                               occur. This alarm occurs in order to verify if either arm is being jammed because it is pressed against a vehicle
                               but the arm did not break away. This “pseudo” break away can only occur once per vehicle.

                          EXCESSIVE POSITION CORRECTION
                               This alarm occurs when Position Resets to ZERO at the Exit Limit but the Carriage Position Error at the time of
                               correction was 30 or greater.