Page 21 - Wave Wrap™
P. 21

WAVE WRAP™


                       Installation


                       Utilities

                          Pneumatic (Air) Connections
                              1)  Run 1/4” airline from the CCU or Air Panel to the oil reservoir hooked up to the rod end side of the
                                 cylinder. Driver side uses RED airline, passenger side used PURPLE airline. This step is for the
                                 WAVE WRAP™ boom extend.
                              2)  Run 1/4” airline from the CCU or Air Panel to port #3 on the WAVE WRAP™ limit switch. Driver
                                 side uses GREEN airline, passenger side used ORANGE airline.
                              3)  Run 1/4” airline from the  CCU or Air Panel to the oil reservoir hooked to the backside  of  the
                                 cylinder. Driver side and passenger side both use  GRAY airline. This step is  for  the  WAVE
                                 WRAP™ boom retract.
                             Driver side                                                             Passenger side







                                                       Main air supply                       Main air supply
                                                       90-PSI minimum                        90-PSI minimum
                                                      120-PSI maximum                       120-PSI maximum


                                     Cylinder
                                    33” stroke                        Flow control valve   Cylinder
                                                                                         6” stroke









                                                             Oil reservoir                  Oil reservoir
                                                              assembly                       assembly



                             Pneumatic valve heavy
                             duty limit switch

                                                                                                          Flow control
                                  Needle valve (leak                                                      valve
                                         control)
                                                                                    Wave Wrap-T™ Boom Extend
                                                                                    From CCU or Air Panel
                                                                                    driver side RED, passenger side PURPLE

                                                                                    Wave Wrap-T™ Boom Retract
                                                                                    From CCU or Air Panel
                                                                                    driver side and passenger side GRAY


                                                                                    Wave Wrap-T™ Head
                                                                                    From CCU or Air Panel
                                                                                    driver side GREEN, passenger side ORANGE






                       1MANUL864              Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681        19