Page 19 - Stainless Steel Mounted UNIARCH
P. 19

Stainless Steel Mounted UNIARCH



                       Maintenance


                       Trouble Shooting

                              Problem                 Cause                             Solution
                          No chemical       •   Clogged foot valve on suction line   •   Clean or replace foot valve
                                            •   Empty storage tank       •   Fill storage tank
                                            •   Chemical pump has lost prime   •   Prime chemical pump
                                            •   Solenoid valve not energized   •   Check for proper operating voltage
                          Pulsating or weak   •   Nozzles clogged        •   Remove from arch manifold and clean with thin wire
                          spray             •   Dirt in solenoid valve   •   Disassemble and clean solenoid valve

                                            •   Kink in hose             •   Remove any kinks from hose
                                            •   Inadequate water pressure   •   Open water valve to fullest
                                                                         •   Call Distributor for advice on installing booster pump
























































                       1MANUL230             Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (810) 349-7010 * Fax (810) 380-9681        17
   14   15   16   17   18   19   20   21   22