Page 21 - Tunnel Support Components
P. 21

TUNNEL SUPPORT COMPONENTS


                       Installation


                       20HP Hydraulic Unit


                          Fluid Cap
                           When doing maintenance, be sure fluid cap is securely tightened so not to allow debris to get inside of
                           the tank.
                                                            CAUTION

                                If the reservoir needs to be refilled, be sure to use the same type used during initial startup.
                                              NEVER mix the two fluid types together!

                          Fluid Level Sensor

                           The sensor requires 24VDC to be supplied. The Fluid Level Sensor
                           can be adjusted to detect various, desired oil levels. This can be very
                           beneficial in a case where the oil  is slightly low and you need  to
                           keep running while more is being sought. In this case you can loosen
                           the  knurled  locking ring and slide the wand deeper into the tank.   Knurled
                           This will prevent the system from shutting down. If  this  becomes   Locking
                           necessary, pay close attention to the pre-set depth of the wand.   Ring

                           Be sure to raise it back to its original position once the oil is returned
                           to the proper level.

                              Note:  DO NOT OPERATE WITH LOW OIL LEVELS FOR EXTENDED PERIODS.

                          Main Electrical Feed
                           The system requires 208/230/460VAC, 3-phase power supplied from the MCC panel.

                          Pressure Adjustment Manifold and Feed Pressure Gauge

                              Note:  Hydraulic pressure is pre-set at the factory
                           To adjust oil pressure:

                                  5)  Open the Snubber Valve.
                                  6)  Turn on the Hydraulic Unit.
                                  7)  Loosen the Locking Nut and adjust  the  pressure  to
                                      1000PSI.
                                  8)  Tighten the Locking Nut and close the Snubber Valve.
                           NEVER READ THE GAUGE WHEN THE  SNUBBER  VALVE  IS
                           CLOSED. IT WILL GIVE FALSE READINGS.


                              Note:  Recommended pressure: 1000 PSI.  Pressure  greater          Locking Nut
                                     than  1000  PSI uses more horsepower and does not
                                     supply more oil flow!
                              Note:  During operation the snubber knob should be closed to
                                     reduce shock to the pressure gauge  from  system   Adjustment
                                                                                      Knob
                                     hydraulic pressure.