            Maintenance


            Routine Procedures

               Foam Bullets™
                   Check spray nozzles
                   Run a test wash to begin each business day
                   Inspect all air-lines making sure they are not making contact with sharp objects or in the path of vehicles
                   Use a warm rag/towel to wipe Foam Bullet™ of any dirt or debris

            Trouble Shooting


                 Problem                  Cause                              Solution
             No chemical           Clogged foot valve on suction line      Clean or replace foot valve

                                   Empty storage tank          Fill storage tank
                                                                                          ®
                                   Chemical pump has lost prime      Prime chemical pump (Flojet or MixStir  are self priming)
                                   Solenoid valve not energized      Check for proper operating voltage

             Pulsating or weak      Dirt in solenoid valve      Disassemble and clean solenoid valve
             spray
                                   Kink in hose                Remove any kinks from hose
                                   Inadequate water pressure      Open water valve to fullest
                                   Spray holes clogged         Remove the fittings and foam bullets and blow the
                                                                 screen to remove any film
                                   Loose or bad fittings
                                                                Disable the Pod and clean with thin wire and blow
                                                                 through each port
                                                                Check all fittings on the complete system to assure that
                                                                 they are tight and do not leak
             LED is not On or      Connection in Foam Bullet™ is      Verify electrical connection is secure
             Flashing               loose
                                                                Replace LED light assembly (110634)
                                   Short in LED light assembly

                  If using a Belanger  MixStir  to supply the Foam Bullets™ refer to that manual (1MANUL450) for troubleshooting
                                       ®
                                 ®
                   any issues and to diagnose any repair or maintenance issues.
                  If using a Belanger  supplied Pulsatron pump assembly with air panel which is a Auto Fluid Injection System
                                 ®
                   (AFIS) to supply the Foam Bullets™ refer to that manual (1MANUL006) for troubleshooting any issues and to
                   diagnose any repair or maintenance issues.