Page 15 - Prep Jet System
P. 15
PREP JET SYSTEM
Initial Startup
This Section Critical to Proper Operation
CAUTION
DO NOT START UNTIL THE TANK HAS BEEN FILLED AND
THE OIL IS AT THE PROPER LEVEL!!!
1) Turn on the power to the pump motor and check rotation.
View from rear of Prep Jet
2) Adjust the pressure of the Prep-Jet System
a) Adjusting the unloader pressure must be done with the system “ON”.
b) Start the system with the unloader backed to the lowest pressure setting.
c) Squeeze the trigger and read the pressure on the gauge at the pump. If more pressure is desired, release the
trigger, turn the adjusting nut 1/4 turn, squeeze the trigger and read the pressure gauge.
d) Repeat this method until desired pressure is attained.
CAUTION
IMPORTANT: DO NOT EXCEED 1000 PSI (68.9 BAR). Pressure fluctuation is minimal with
the opening of each additional gun.
e) Once the desired pressure is reached, set the top locking nut to hold the pressure.
CAUTION
DO NOT ADJUST THE UNLOADER PRESSURE TO COMENSATE FOR WORN
NOZZLES.
f) Checking nozzle wear should be part of the regular maintenance.
CAUTION
AFTER THE FIRST 100 HOURS OF OPERATION, CHANGE THE OIL IN
THE PUMP. REPLACE ONLY WITH CAT™ WHICH CAN BE ACQUIRED
THROUGH YOUR DISTRIBUTOR OR BELANGER, INC. OIL IS TO BE
CHANGED EVERY 500 HOURS THEREAFTER.
CAUTION
DO NOT ROTATE PUMP WHEN OIL RESERVOIR IS EMPTY.
1MANUL603 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 13