Page 48 - FreeStyler® E-1063 Programming and Operation Manual
P. 48

E-1063 PROGRAMMING AND OPERATION


            Chapter 5 Operator Interface/Advanced Configuration


            Setup / Advanced Configuration


                Advanced Configuration / Application Configuration
            NAMED 1 - 8
               NAMED       ON or OFF       ON          ON          OFF         TM          PGM
            TF CHEM (typical)   YES / NO   FS / FE 000   FS / FE 000   FS / FE 000   YES / < >   YES / NO
            Name of OUTPUT.   Toggles   Toggles between FS and FE.   Toggles   Toggles   Toggles
            Typically renamed   between YES   FS stands for “From Start”. FE   between FS   between YES   between YES
            to match the   and NO.     stands for “From End”. The three   and FE.   and < >.   and NO.
            application.   If set to YES,   zeros are the “Measured in   FS stands for   If set to YES,   If set to YES,
                           the Output will   Inches” field.    “From Start”.   the Output will   the Output will
                           function with    Each NAMED 1 – 8 have two ON   FE stands for   turn OFF while   remain ON at
                           that        positions.              “From End”.   over pick-up   the end of the
                           application.                        The three    truck bed.   application

                                                               zeros are the   The OFF   until Purge
                                                               “Measured in   position is   time is done.
                                                               Inches” field.   adjustable from
                                                               Each NAMED   the “TRUCK
                                                               1 – 8 have one   MODE
                                                               OFF position.   OFFSET” field.
                                                               They all turn
                                                               OFF at the end
                                                               of application.
            MISCELLANEOUS NAMED 1 - 8

             MISC NAMED      ON or OFF        ON             OFF           PFFA           PGM
            TIRE APP (typical)   YES / NO   FS / FE 000   FS / FE 000     YES / NO      YES / NO
            Name of OUTPUT.   Toggles between   Toggles between   Toggles between   Toggles between   Toggles between
            Typically renamed   YES and NO.   FS and FE.   FS and FE.   YES and NO.   YES and NO.
            to match the   If set to YES, the   FS stands for   FS stands for   PFFA stands for   If set to YES, the
            application.   Output will function   “From Start”. FE   “From Start”. FE   “Position From   Output will remain
                           with that     stands for “From   stands for “From   Front Always”.   ON at the end of
                           application.   End”.         End”.                         the application until
                                         The three zeros   The three zeros            Purge time is
                                         are the “Measured   are the “Measured        done.
                                         in Inches” field.   in Inches” field.
                                         Each MISC      Each MISC 1-8
                                         NAMED 1 – 8 have  have one OFF
                                         one ON position.   position.






















             5-2               Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681                    1MANUL224