Page 53 - FreeStyler® E-1063 Programming and Operation Manual
P. 53
E-1063 PROGRAMMING AND OPERATION
Chapter 5 Operator Interface/Advanced Configuration
Setup / Advanced Configuration
Advanced Configuration / Enter Wheel Setup
Screen Key
•
MONITOR RETRACT: The oval toggles from filled to un-filled. When filled the system will Fault if the Arms are
being instructed to open and either of the Out-Position Read Sensors are not on.
FROM FRONT: Indicates that the Application started at the exit of the bay (front of the vehicle). The following
fields control Enter Wheel behavior when they are started From Front.
ENABLED / DISABLED CHECK NEXT PASS
• When ENABLED the Enter Wheels will stay on and in until next pass is started.
• If next pass does not utilize Enter Wheels, the Enter Wheels will go out and turn off.
• If next pass does utilize Enter Wheels, they will remain in and on for uninterrupted operation
ENABLED / DISABLED ANTI SKUNK
• When ENABLED the Enter Wheels will perform “Anti-Skunk” motion at the rear of the vehicle
when started FROM FRONT.
• ANTI SKUNK DISTANCE: This is the amount of inches after Enter Passenger Side In (Input / X35) in on
that the carriage will continue to travel backward. Once the Carriage has traveled this far backward, it will
move passenger side arm out, move the driver side in and then move forward 10 inches before finishing
pass.
FROM FRONT IN MOTION DELAY
• This is the amount of seconds that the Carriage motion will be delayed after Enter Wheels are
instructed to come in when the pass has started FROM FRONT.
ENABLED / DISABLED SPEED SHIFT
• When ENABLED and the machine is within the SPEED SHIFT POSITION from the back of
vehicle the machine will slow down.
• SPEED SHIFT POSITION: This is the amount of inches from the back of the vehicle that the Carriage
will slow down to allow the Enter Wheels more time on the back of the vehicle.
• SPEED SHIFT SPEED: This is the speed that the Carriage will travel when SPEED SHIFT is active on
the back of the vehicle. Displayed in Hz. Value is relative. Smaller values produce slower speeds.
1MANUL224 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 5-7