Installation
Utilities: Pneumatic, Water and Electrical
Pneumatic Distribution Manifold Installation
1) Remove the utility Distribution Manifold Assembly from the accessory box.
Note: This assembly will mount on the bottom side of the upper head beam & either on the
driver side or the passenger side of the frame, depending on what side your equipment
room is on. In this manual we will show the manifold assembly mounted to the
passenger side of the machine.
2) Attach the Distribution Manifold Assembly to the frame using the hardware that is shipped and
attached to it as shown below.
Wedged shaped nuts
go in the slot of the
frame
Airline fittings face
the exit of the tunnel
Pneumatic (Air) Panel Mounting and Supply Feed
1) Remove the air panel assembly from the accessory box and mount it in the location specified on
your site drawings using the 4 corner holes that are on the air panel plate. The mounting supplies
are field supplied.
2) Run a 1/4” field supplied airline from the main air supply to the straight fitting that is located on the
bottom of the air panel valve.
Main Air Feed
34 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL248