Page 13 - Foaming Pods
P. 13
FOAMING PODS
Specifications
Requirements
Physical
Tunnel space required 15” Coverage
Utility
Electrical 110 VAC @ 5 amps minimum
1 or 2 Outputs
Hose 1/2” poly-flow line for main feed
1/4” poly-flow line to feed Pod Distribution Blocks
(quantity will vary from site to site)
Pneumatic 15 SCFM @ 50 PSI air flow (minimum) to 1/2” poly-flow
Water 5 GPM fresh water feed (minimum) to 3/4” hose barb
Note: We recommended the use of “clear” transfer hose for chemicals and “black” transfer hose
for air.
DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE SERVICING ANY
EQUIPMENT!
CAUTION
Always wear safety glasses when performing maintenance on any equipment
CAUTION
It is recommended that a licensed electrician is contracted to perform all electrical
installations.
CAUTION
A compressed Air System should be set correctly to support 90 PSI necessary to operate
equipment, but should never be set to deliver more than 120 PSI air pressure to the Belanger
specified equipment.
®
Belanger, Inc. 1995
This manual and the accompanying equipment are protected by United States and International copyright and patent
laws. You may make one copy of this manual. Do not make additional copies of this manual or electronically transmit
it in any form whatsoever, in whole or in part, without the prior written permission of Belanger, Inc.
®