Page 32 - Foaming Pods
P. 32
FOAMING PODS
Utility Connections
Connections for Electrical Distribution Block
CAUTION
Controller Contact MUST be rated at 2AMPS or more
Not Used: PORT 7
PORT 8: Solenoid Valve #2 (Air)
Chemical Pump #3: PORT 5
PORT 6: Solenoid Valve #1 (Air)
Chemical Pump #2: PORT 3
PORT 4: ASCO Valve #2 (Water)
Chemical Pump #1: PORT 1 PORT 2: ASCO Valve #1 (Water)
Dual Panel Configuration
Output
1 Port 1 Signal 2 Gray/Pink N/C
2 Port 1 Signal 4 White Triple Foam Chemical #1
3 Port 2 Signal 2 Red/Blue ASCO Valve #1 (Water)
4 Port 2 Signal 4 Green N/C
5 Port 3 Signal 2 White/Green N/C
6 Port 3 Signal 4 Yellow Triple Foam Chemical #2
7 Port 4 Signal 2 Brown/Green ASCO Valve #2 (Water)
8 Port 4 Signal 4 Gray N/C
9 Port 5 Signal 2 White/Yellow N/C
10 Port 5 Signal 4 Pink Triple Foam Chemical #3
11 Port 6 Signal 2 Yellow/Brown Solenoid Valve #1 (Air)
12 Port 6 Signal 4 Red N/C
13 Port 7 Signal 2 White/Gray Spare
14 Port 7 Signal 4 Black N/C
15 Port 8 Signal 2 Gray/Brown Solenoid Valve #2 (Air)
16 Port 8 Signal 4 Violet N/C
17 Power Brown Ground
18 Neutral Blue Common
19 Ground Green/Yellow Ground
30 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (810) 349-7010 * Fax (810) 380-9681 1MANUL770