Page 33 - Foaming Pods
P. 33

FOAMING PODS


                       Utility Connections


                       Connections for DCC or Alternative Controller to Dual Panel

                       As noted earlier in the manual, the Dual Panel can be utilized in two different setups.
                          •   One setup would allow you to run the standard triple foam when that package is selected.

                          •   The second setup would allow you to bundle three separate packages within the whole foam
                              pod/dual panel system.
                       Within this setup you can fire a single foam package, a double foam package, or the triple  foam
                       package. This will be based on the customer’s preference.
                          DCC CONNECTIONS
                                                                  Setup #1
                                                     DCC when using the triple foam at all times
                                Output                     Name                              Wiring
                            640              Triple Foam Water                  red/blue and brown/green
                            641              Triple Foam Air                    yellow/brown and gray/brown
                            642              Triple Foam Chemical #1            white
                            643              Triple Foam Chemical #2            yellow
                            644              Triple Foam Chemical #3            pink

                                                                  Setup #2

                                      DCC when Using the three package setup. (single foam; double foam; triple foam)
                                Output                     Name                              Wiring
                            640              Triple Foam Water                  brown/green
                            641              Triple Foam Air                    gray/brown
                            642              Triple Foam Chemical #1            no connection
                            643              Triple Foam Chemical #2            yellow
                            644              Triple Foam Chemical #3            pink
                             The 630 setting shown below is a spare.. This is to be used when the second setup is utilized and only to fire the
                            single foam package. It will fire chemical pump #1, ASCO valve #1(water), and solenoid valve #1(air). When wanting
                             to fire double foam only, use outputs 640 thru 644 only. If wanting to fire the triple foam package, use outputs 640
                                                                thru 644 and 630.
                            630              Named 2-1 on the DCC               red/blue and yellow/brown and white

                          ALTERNATIVE CONTROLLER CONNECTIONS
                                                                   Setup
                                              The following setup is for the use of the three-package system
                            Function to control the single bank   red/blue and yellow/brown and white
                            Function to control the double bank   brown/green and gray/brown and yellow and pink