FOAMING PODS
Utility Connections
Connections for DCC or Alternative Controller to Dual Panel
As noted earlier in the manual, the Dual Panel can be utilized in two different setups.
• One setup would allow you to run the standard triple foam when that package is selected.
• The second setup would allow you to bundle three separate packages within the whole foam
pod/dual panel system.
Within this setup you can fire a single foam package, a double foam package, or the triple foam
package. This will be based on the customer’s preference.
DCC CONNECTIONS
Setup #1
DCC when using the triple foam at all times
Output Name Wiring
640 Triple Foam Water red/blue and brown/green
641 Triple Foam Air yellow/brown and gray/brown
642 Triple Foam Chemical #1 white
643 Triple Foam Chemical #2 yellow
644 Triple Foam Chemical #3 pink
Setup #2
DCC when Using the three package setup. (single foam; double foam; triple foam)
Output Name Wiring
640 Triple Foam Water brown/green
641 Triple Foam Air gray/brown
642 Triple Foam Chemical #1 no connection
643 Triple Foam Chemical #2 yellow
644 Triple Foam Chemical #3 pink
The 630 setting shown below is a spare.. This is to be used when the second setup is utilized and only to fire the
single foam package. It will fire chemical pump #1, ASCO valve #1(water), and solenoid valve #1(air). When wanting
to fire double foam only, use outputs 640 thru 644 only. If wanting to fire the triple foam package, use outputs 640
thru 644 and 630.
630 Named 2-1 on the DCC red/blue and yellow/brown and white
ALTERNATIVE CONTROLLER CONNECTIONS
Setup
The following setup is for the use of the three-package system
Function to control the single bank red/blue and yellow/brown and white
Function to control the double bank brown/green and gray/brown and yellow and pink