Page 42 - Sudzer® BL & FM
P. 42

®
            SUDZER  BL & FM



            Chapter 3 Sudzer® BL Installation

            Sudzer® BL Utilities
                                                ®
               Electrical Connections: Sudzer  BL Inline Fan
                          ®
               The Sudzer  BL Air Plenum Inline Fan is a two speed 120 vac motor.
               1)  Wire the motor inside the enclosure on top of the passenger side of the Air Plenum for high
                   speed, as shown in the image below.

                                                           Note:  Be  sure  to  follow  local  electrical  codes
                                                                 when choosing wiring materials and when
                                                                 routing electrical wires.


                                                           Note:  The  Inline  Fan  should  have  a  separate
                                                                 electrical  output  so  that  it  may  be
                                                                 programmed separately from the Chemical
                                                                 Delivery Device and the Wall Washers.




               2)  Route the wire from the Fan enclosure to the backroom and connect it to an output on the
                   Controller.

               3)  Test to see if the Fan is functioning properly by using the Controller to turn on the Fan.

               Electrical Connections: Wall Washers (Light Bars)

                 Note:  For  a  SpinLite  System  the  Wall  Washers  WILL  be  connected  to  a  SpinLite  Lighting  Panel
                       therefore  a  24VDC  Electrical  Power  Supply  WILL  NOT  be  included,  refer  to  the  SpinLite
                       Lighting Panel Manual to make the proper electrical connections for the Wall Washers.

               1)  Included  with  the  Sudzer®  BL  is  an  electrical enclosure with a 24VDC power supply to be
                   used to power the Wall Washers, mount this enclosure in the backroom

               2)  The two electrical wires that are coming out of the cord grips on top of the Air Plenum are for
                   the Wall Washers. These wires are to be routed and connected to the 24VDC power supply.
                   Wire for DS Wall Washer
                 Wire for PS Wall Washer                     Note:  Be  sure  to  follow  local  electrical  codes
                                                                    when choosing wiring materials and when
                                                                    routing electrical wires.


                                                             Note: The Wall Washers should have a separate
                                                                    electrical  output  so  that  they  may  be
                                                                    programmed separately from the Chemical
                                                                    Delivery Device and the Inline Fan.

               3)  For  proper  wiring  inside  of  the  24VDC  Power  Supply  Enclosure  refer  to  the  Wire Diagram
                   provided.
               4)  Connect the 24VDC Power Supply to an output on the car wash controller.
            1MANUL026         Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681     3-16