Page 56 - Sudzer® BL & FM
P. 56
®
SUDZER BL & FM
Chapter 4 Sudzer® FM Installation
Sudzer® FM Assembly
Installing the Sudzer® FM Nozzles
4) Remove the Utility Mount Plate from the Air Plenum to access the Utility Manifold.
Swivel Two-Way Fitting Entrance Side of Tunnel
Fastner with
Arm Knob
Utility Mount Plate
Air Plenum
Utility Manifold Asy.
Exit Side of Tunnel
5) The three two-way fittings on the entrance side of the Utility Manifold are to supply the
Nozzles with the chemical solution and the three two-way fittings on the exit side of the Utility
Maniforld are to supply the Nozzles with compressed air, refer to the image below.
Entrance Side of Tunnel
Utility Manifold Fittings
Exit Side of Tunnel for Chemical Solution
Utility Manifold Fittings
for Compressed Air
6) Retrieve two hoses, one natural and one black, of equal length. Connect the black hose to a
fitting on the compressed air side and the natural hose to a fitting on the chemical solution
side of the Utility Manifold. Route the connected hoses through the Air Plenum and connect
them to the fitting on the appropriate Nozzle.
1MANUL026 Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 4-6