7) After the chemical and air hoses have been connected to a Nozzle install the Nozzle into the
Air Plenum. Rotate the Nozzles to the left so that the keyed flange will fit into the keyed
opening in the Air Plenum, as shown below.
Air Plenum
Hoses for the Chemical
Solution & Compressed
Air are connected to the Chemical Solution &
Utility Manifold Compressed Air are
connected to Nozzle
Nozzle
8) If the the Optional RGB LED Nozzles were purchased the electrical wires for the Nozzle LEDs
will need to be connected before the Nozzles are installed into the Air Plenum.
Route the LED Harness Assembly from the Utility Mount Plate through the Air Plenum
align the six electrical plugs on the harness with each of the Nozzle Outlets in the Air
Plenum.
Before connecting the quick connectors between the Wire Harness and the Nozzle
LED apply a small amount of dielectric grease to the receptor side of the connection.
Connect the electrical plug from the Wire Harness into the electrical receptor on the
LED in the Nozzle, as shown below.
Plug from LED Wire Harness
Receptor for LED in Nozzle
Note: Apply a small amount of dielectric
grease on the receptor side of the
connection and push the connectors
together making sure to align them
for a proper seat.
1MANUL026 Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 4-7