Page 65 - Sudzer® BL & FM
P. 65

®
                       SUDZER  BL & FM



                       Chapter 4 Sudzer® FM Installation

                       Sudzer® FM Utilities

                          Electrical Connections: Optional LED Output Nozzles

                            Note:  For  a  SpinLite  System  the  LED  Nozzles  WILL  be  connected  to  a  SpinLite  Lighting  Panel
                                  therefore  a  24VDC  Electrical  Power  Supply  WILL  NOT  be  included,  refer  to  the  SpinLite
                                  Lighting Panel Manual to make the proper electrical connections for the LED Nozzles.

                          1)  If the option to have RGB LED Nozzles was selected there will be an electrical enclosure with
                              a 24VDC 5.5A power supply  to power the LED in the nozzles, mount this enclosure in the
                              backroom.
                          2)  Run the Main Power Cable for the LED Nozzles from the Power Enclosure out to the Sudzer®
                              and through the center cord grip at the top of the Air Plenum.


                                                       Center Cord Grip








                                Main Power Cable
                                 for LED Nozzles





                          3)  Loosen the three fasteners on the Utility Plate and pull the Utility Plate out of the Air Plenum
                              slightly to gain access to the Wire Harness for the LED Nozzles, as shown below.



















                                                                                    Note: The Chemical Solution and
                                                                                    Compressed Airlines connecting the
                                                                                    Utility Manifold to the Nozzles have been
                                                                                    removed for clarity.

                          4)  Apply a small amount of dielectric grease to the receptor on the Wire Harness then connect
                              the Main Power Cable to the Wire Harness Assembly, as shown above.
                          5)  Reassemble the Utility Plate to the Air Plenum.

                          6)  Using the Controller, turn on the RGB LED Nozzles to make sure they are working properly.
                       1MANUL026        Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681   4-15