            SUDZER  BL & FM



            Chapter 4 Sudzer® FM Installation

            Sudzer® FM Utilities

               Connecting the MixStir® to the Sudzer® FM
               At this point, the MixStir® Chemical Delivery System should be in place and operational.

                 Note: It is recommended that the MixStir® Chemical Delivery Device be installed as close to the
                             ®
                       Sudzer  FM as possible to ensure optimal performance.
                 Note:  A  minimum  of  a  ½”  diameter  airline  is  required  for  the  Compressed  Air  Feed  and  the
                       Chemical Solution Feed.
               1)  Replace  the  ¼”  elbow  fitting  on  the  Regulator  of  the  MixStir®  with  the  supplied  ½”  elbow
                   fitting.
                                                              2)  Run the Compressed Air Line Feed from
               Connect Line for   MixStir® Air Pump Panel
               Compressed Air                                    the Pneumatic Regulator on the MixStir®
                                                                 out to the passenger side of the  bay.
                                                              3)  Run  the  Chemical  Solution  Airline  Feed
                                                                 from the Pump on the MixStir® out to the
                                                                 passenger side of the bay.
               Supplied ½” Elbow
                 Fitting to replace                           4)  Turn  on  the  MixStir®  to  verify  that  the
                   current fitting                               chemical is getting out to the bay and to
                                                                 flush  out  any  unwanted  debris  that  may
                    Pneumatic                                    be in the line.
                    Regulator                                 5)  The  MixStir®  will  be  connected  to  the
                                                        Pump
                                                                 Sudzer® through the fittings on the Utility
                                                                 Mount  Plate  located  on  the  passenger
                                                                 side of the Air Plenum.
                                                              6)  Connect the Chemical Solution Feedline
                                                                 to the Utility Mount Plate Fitting closest to
                                                Connect Line for   the  entrance  side  of  the  Sudzer®  and
                                                Chemical Solution   connect the Compressed Air Line to the
                                                                 Utility  Mount  Plate  Fitting  closest  to  the
                                                                 exit side of the Air Plenum.
               7)  Turn on the MixStir®, make sure that the solution is spraying out of all six Nozzles properly.


                                                                  Exit Side

                                                                Utility Mount   Compressed Air
                                                                Plate      Main Feed Line








                   Entrance Side
                                                      Chemical Solution
                                                        Main Feed Line



                                                       Passenger Side