Page 414 - Foton Workshop Manual - Auman EST-M
P. 414

DI - 360             Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts


                                                        d. Use a multimeter to measure the voltage between 1# and
                                                        2# terminals of cab unlocked switch connector G0065.
                                                        Standard voltage:

                                                         Multimeter connecting terminal   Standard value

                                                               G006(1)-G006(2)         Storage battery voltage




                                                        e.  Measure  the  voltage  between  the  cab  unlocked  switch
                                                        connector  G006  terminal  2  and  the  ground  with  the
                                                        multimeter in voltage gear.
                                                        Standard voltage:

                                                            Multimeter connecting
                                                                                         Standard value
                                                                  terminal

                                                              G006(2)- grounding      Storage battery voltage

              Check if the result is ok?

              Yes> replace cab unlocked switch.
              No> if no battery voltage, go to Step 5.

              5. Check the driver cab unlocked signal circuit for open circuit

                                                        a. Measure the voltage between the combination instrument
                                                        connector  B014  terminal  21  and  the  ground  with  the
                                                        multimeter in voltage gear.
                                                        Standard voltage:

                                                          Multimeter connecting terminal   Standard value


                                                               B004(21)-grounding      Storage battery voltage


              Check if the result is ok?
              Yes > repair or replace the signal circuit.
              NO>retest the above steps.




















                                                          DI-360
   409   410   411   412   413   414   415   416   417   418   419