Page 2138 - Foton Workshop Manual - Aumark (BJ1099)
P. 2138
62-86 DIAGNOSIS-REVERSING RADAR
Fault phenomenon Possible reasons Refer to
U010B-78 Chapter 46 Diagnosis; Reversing
reversing radar; LIN 1.Reversing radar probe damaged aid - Replacement, reversing
communication fault; radar probe
LIN1 reversing radar 2.Short circuit or open circuit of wiring
communication error harness Maintain or change
U0112-78 Reversing 1.Fuse damaged Change
radar power supply 2.Reversing lamp relay damaged Change
faulted; LIN1 reversing
radar communication 3.Short circuit or open circuit of wiring Maintain or change
error harness
U010C-78; ROL camera
faulted; LIN1 reversing Chapter 46 Diagnosis; Reversing
radar communication 1.Reversing radar probe damaged aid - Replacement, reversing
error radar probe
U010D-78; RML camera
faulted; LIN1 reversing Chapter 47 Vehicle control
radar communication 2.BCM (body control module) faulted system - Replacement, BCM
error (body control module)
U010E-78; RMR
camera faulted;
LIN1 reversing radar
communication error
U010F-78; ROR camera
faulted; LIN1 reversing
radar communication
error
U0110-78; FOL camera 3.Short circuit or open circuit of wiring Maintain or change
faulted; LIN1 reversing harness
radar communication
error
U0111-78; FOR camera
faulted; LIN1 reversing
radar communication
error
Page 2138