Page 2177 - Foton Workshop Manual - Aumark (BJ1099)
P. 2177
DIAGNOSIS-POWER DOOR LOCK 62-125
Diagnosis Procedure
1. Check the fuse
(a). Ignition switch:"LOCK".
62
(b). Check the nacelle fuse box fuse:
F13(30A)、F2(60A).
Disconnect Normal
(c). Check the fuse in the indoor fuse box:
F1(15A).
fuwx62452
Check if the fuse is well.
Yes>To step2.
No >Replace the fuse.
2. Check harness and connector (F1(15 A)-body controller circuit)
(a). Measure the voltage between the
grounding and the No.B6 pin of the
connector C55 on the body controller with
the multimeter.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
C55 (B6) - Grounding Battery volt
Is the result normal?
Yes>To step3.
No >Repair or replace the harness.
3. Check the harness and connector (the central locking switch-grounding)
(a). Disconnect the connector J10 of the central locking switch.
Page 2177