Page 2178 - Foton Workshop Manual - Aumark (BJ1099)
P. 2178
62-126 DIAGNOSIS-POWER DOOR LOCK
(b). Measure the resistance between the
grounding and the No.1 pin of the
connector J10 on the central locking switch
with the multimeter.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
J10 (1) - Grounding < 2 Ω
Is the result normal?
Yes>To step 4.
No >Repair or replace the harness.
4. Check the body controller power supply circuit
(a). Disconnect the body controller connector C57.
(b). Measure the resistance between the
grounding and the No.D6 pin of the
connector C57 on the body controller with
the multimeter.
Standard resistance: (check whether there
is a short circuit)
Connect by Standard value
multimeter
C57 (D6) - Grounding > 1 MΩ
Is the result normal?
Yes>To step5.
No >Replace the body controller.
Page 2178