DIAGNOSIS-POWER DOOR LOCK                                62-127

                 5.     Check the harness and the connector ( body controller-central lock position switch)


                                                            (a).   Disconnect the connector J10 of the central
                                                                   locking switch.

                                                                                                                    62





















                                                            (b).   Disconnect the connector C58 of the body
                                                                   controller.





















                                                 fuwx62302

                                                             (c).   Measure the resistance between the No.2
                                                                   pin of the connector J10 on the central
                                                                   locking switch and the No.D6 pin of the
                                                                   connector C57 of the body controller with
                                                                   the multimeter.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by       Standard value
                                                                          multimeter
                                                                       J10 (2) - C57 (D6)          < 2 Ω