DIAGNOSIS-POWER DOOR LOCK 62-129
(b). A multimeter is used to measure the
resistance between the No.4 pin of the
driver door locks connector J07 and the
grounding.
Standard resistance: (check whether there
is an open circuit) 62
Connect the pin by Standard value
multimeter
J07 (4) - Grounding < 2 Ω
Is the result normal?
Yes>To step 8.
No >Repair or replace the harness.
8. Check the harness and the connector ( body controller-grounding)
(a). Disconnect the connector C58 of the body
controller.
fuwx62303
(b). Measure the resistance between No.E15
and No.E30 pin of body controller
connector C58 and the grounding with the
multimeter.
Standard resistance: (check whether there
is a short circuit)
Connect the pin by Standard value
multimeter
C58 (E15) - Grounding > 1 MΩ
C58 (E30) - Grounding > 1 MΩ