DIAGNOSIS-LIGHTING SYSTEM 62-321
(d). Connect the positive and negative
electrode of the bulb to the positive
and negative electrode of the battery
respectively to check if the bulb will light
up.
62
Is the result normal?
Yes>To step 3.
No >Replace the bulb.
3. Check the high beam lamp relay
(a). Ignition switch:"LOCK".
(b). Pull out the high beam lamp relay R6.
(c). Check the high beam lamp relay R6.
Connect
Condition the pin by Specified
value
multimeter
Apply the power
supply voltage
between the 3-5 Existed
No.1 and No.2
pin
Ordinary state 1-2 <2Ω
Is the inspection result normal?
Yes>To step 4.
No >Replace the high beam lamp relay.
4. Check the harness disconnection
(a). Ignition switch:"LOCK".
(b). Disconnect the left front combination lamp connector A28.
(c). Disconnect the right front combination lamp connector A03.
Page 2373