Page 2373 - Foton Workshop Manual - Aumark (BJ1099)
P. 2373

DIAGNOSIS-LIGHTING SYSTEM                               62-321

                                                            (d).   Connect the positive and negative
                                                                   electrode  of  the  bulb  to  the  positive
                                                                   and negative electrode of the battery
                                                                   respectively to check if the bulb will light
                                                                   up.
                                                                                                                    62







                 Is the result normal?
                 Yes>To step 3.
                 No >Replace the bulb.


                 3.     Check the high beam lamp relay


                 (a).   Ignition switch:"LOCK".
                 (b).   Pull out the high beam lamp relay R6.


                                                            (c).   Check the high beam lamp relay R6.

                                                                                        Connect
                                                                       Condition        the pin by    Specified
                                                                                                        value
                                                                                       multimeter
                                                                     Apply the power
                                                                     supply voltage
                                                                      between the          3-5          Existed
                                                                     No.1 and No.2
                                                                          pin

                                                                      Ordinary state       1-2           <2Ω
                 Is the inspection result normal?
                 Yes>To step 4.
                 No >Replace the high beam lamp relay.


                 4.     Check the harness disconnection


                 (a).   Ignition switch:"LOCK".
                 (b).   Disconnect the left front combination lamp connector A28.
                 (c).    Disconnect the right front combination lamp connector A03.















                                                                                                     Page 2373