62-322                           DIAGNOSIS-LIGHTING SYSTEM


                                                      (d).    Turn the combination switch to the "high
                                                              beam lamp"gear, measure the voltage of
                                                              the teminal 1 of the left front combination
                                                              lamp connectors A28 and A03, and also the
                                                              voltage between that and the grounding.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter
                                                                A28(1) - Grounding         Battery volt

                                                                A03(1) - Grounding         Battery volt

           Is the inspection result normal?
           Yes>To step 5.
           No >Repair the harness disconnection between both the left front combination lamp
                   connector A28 and the right front combination lamp connector A03 and the high beam
                   lamp fuse.


           5.     Check harness short circuit to the grounding


           (a).   Ignition switch:"LOCK".
           (b).   Disconnect the left front combination lamp connector A28.
           (c).    Disconnect the right front combination lamp connector A03.


                                                      (d).    Measure the resistance between both No.1
                                                              terminal of the left front combination lamp
                                                              connector A28 and No. 1 terminal of the
                                                              right front combination lamp connector A03
                                                              and the grounding with a multimeter.
                                                              Standard resistance: (check whether there
                                                              is a short circuit)

                                                               Connect the pin by       Standard value
                                                                   multimeter

                                                                A28(1) - Grounding          > 1 MΩ
                                                                A03(1) - Grounding          > 1 MΩ

           Is the inspection result normal?
           Yes>To step 6.
           No >Repair the short circuit to ground of the harness between both the left front
                   combination lamp connector A28 and the right front combination lamp connector A03
                   and the high beam lamp fuse.