Page 2389 - Foton Workshop Manual - Aumark (BJ1099)
P. 2389
DIAGNOSIS-LIGHTING SYSTEM 62-337
(c). Turn the combination switch to the "high
beam lamp" gear, use a multimeter to
measure that the continuity between
No. 7 terminal and No. 8 terminal of the
combination switch shall be existed.
62
Is the inspection result normal?
Yes >Replace BCM control unit.
No >Replace the combination switch.