Page 2389 - Foton Workshop Manual - Aumark (BJ1099)
P. 2389

DIAGNOSIS-LIGHTING SYSTEM                               62-337

                                                            (c).   Turn the combination switch to the "high
                                                                   beam lamp" gear, use a multimeter to
                                                                   measure that the continuity between
                                                                   No. 7 terminal and No. 8 terminal of the
                                                                   combination switch shall be existed.
                                                                                                                    62






                 Is the inspection result normal?
                 Yes >Replace BCM control unit.
                 No >Replace the combination switch.