Page 2386 - Foton Workshop Manual - Aumark (BJ1099)
P. 2386
62-334 DIAGNOSIS-LIGHTING SYSTEM
(d). Connect the positive and negative
electrode of the bulb to the positive
and negative electrode of the battery
respectively to check if the bulb will light
up.
Is the result normal?
Yes>To step 3.
No >Replace the bulb.
3. Check the front fog lamp relay
(a). Ignition switch:"LOCK".
(b). Pull out the front fog lamp relay R07.
(c). Check the front fog lamp relay R07.
Connect
Conditions the pin by Specified
value
multimeter
Apply the power
supply voltage
between the 3-5 Existed
No. 1and No. 2
pin
Ordinary state 1-2 <2Ω
Is the inspection result normal?
Yes>To step 4.
No>Replace the front fog lamp relay.
4. Check the harness and the connector (front fog lamp relay - BCM body controller)
(a). Ignition switch:"LOCK".
(b). Disconnect the front fog lamp relay R07.
(c). Disconnect BCM body controller C57.
Page 2386