Page 2392 - Foton Workshop Manual - Aumark (BJ1099)
P. 2392
62-340 DIAGNOSIS-LIGHTING SYSTEM
Is the inspection result normal?
Yes>To step 3.
No >Repair or replace the harness which has a short circuit to ground between C57 and
the front fog lamp relay R07.
3. Check the fog lamp connector
(a). Ignition switch:"LOCK".
(b). Disconnect the fog lamp relay R07.
(c). Check the front fog lamp relay R07.
Connect
Conditions the pin by Specified
value
multimeter
not
Ordinary state 3-5
existed
Is the inspection result normal?
Yes>To step 4.
No >Replace fog lamp relay.
4. Detect the short circuit to ground of the combination switch
(a). Ignition switch:"LOCK".
(b). Disconnect the combination switch connector C16.
(c). Turn the combination switch to the "front fog lamp" gear.
(d). Measure the resistance between No. 8 pin
of the combination switch connector C16
and the grounding with a multimeter.
Connect the pin by Specified value
multimeter
C16(8) - Grounding Infinite
Is the inspection result normal?
Yes>To step 5.
No >Repair or replace the harness of the short circuit to ground between C58 and the
combination switch C16.
Page 2392