Page 2392 - Foton Workshop Manual - Aumark (BJ1099)
P. 2392

62-340                           DIAGNOSIS-LIGHTING SYSTEM


           Is the inspection result normal?
           Yes>To step 3.
           No >Repair or replace the harness which has a short circuit to ground between C57 and
                   the front fog lamp relay R07.


           3.     Check the fog lamp connector


           (a).   Ignition switch:"LOCK".
           (b).   Disconnect the fog lamp relay R07.


                                                      (c).    Check the front fog lamp relay R07.

                                                                                  Connect
                                                                Conditions       the pin by     Specified
                                                                                                  value
                                                                                 multimeter
                                                                                                    not
                                                               Ordinary state        3-5
                                                                                                  existed




           Is the inspection result normal?
           Yes>To step 4.
           No >Replace fog lamp relay.


           4.     Detect the short circuit to ground of the combination switch


           (a).   Ignition switch:"LOCK".
           (b).   Disconnect the combination switch connector C16.
           (c).    Turn the combination switch to the "front fog lamp" gear.


                                                       (d).   Measure the resistance between No. 8 pin
                                                              of the combination switch connector C16
                                                              and the grounding with a multimeter.


                                                               Connect the pin by       Specified value
                                                                   multimeter
                                                                C16(8) - Grounding           Infinite



           Is the inspection result normal?
           Yes>To step 5.
           No >Repair or replace the harness of the short circuit to ground between C58 and the
                   combination switch C16.








                                                                                                     Page 2392