DIAGNOSTICS - LIGHTING SYSTEM                            04-891

                                                           (d)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                                                                                                     04
                                              C036            C036(E12) - C008                  < 2 Ω
                                                                     (18)





                                             C008









                                                 ftwxd041402

                 Check whether the result is normal?

                 Yes> Replace BCM control unit.
                 No > Maintenance or replace harness.