       Technical Characteristics                                                                 Cleaning, Disinfection and sterilization
                      Specification                       Description                              N°       Operation          Operating mode            Warning
                                                 Not suitable for use in the                                               1. Once the accessories have
        Safety level in the presence of flammable   presence of flammable anesthetic                                       been cleaned and inspected,   The hook mechanism has to be
                                                                                                                           place them into the disinfection
        anesthetic gas mixtures or oxygen        mixtures with air, oxygen or                                              bath for the prescribed contact   activated several times during
                                                 nitrous oxide                                                             time (e.g. Cidex OPA, Johnson   disinfection and the rinse to
                                                                                                                                                  allow the inner parts to be
                                                                                                                           & Johnson Medical, 100% for
        Mode of operation                        Continuous operation                                                      20 minutes); the accessories   disinfected more effectively.
                                                                                                                           must be sufficiently immersed in
        Ingress of liquids                       Not protected                                    4.    Disinfection       the solution.          To dry use oil-free, filtered
                                                                                                                                                  compressed air and then leave
                                                 •  Use: in enclosed spaces                                                2. Remove the accessories from   the accessories to dry further in
                                                 •  Ambient temperature:                                                  the disinfection bath and rinse   a clean place for at least
                                                                                                                                                  20 minutes.
                                                    10°C - 40°C                                                           them off thoroughly at least five
                                                                                                                           times for a minute each time with
                                                    (50°F - 104°F)                                                         water.                 Once the accessories are dry,
                                                                                                                                                  inspect and pack them as soon
        Ambient conditions                       •  Relative humidity:                                                    3. Dry the accessories by   as possible.
                                                    10% - 90%,                                                            blowing them down fully.
                                                    non-condensing                                                                                Use quality water in accordance
                                                 •  Operating altitude:                                                                          with local regulations.
                                                    106 kPa to 70 kPa
                                                                                                                                                  If a disinfecting solution contains
                                                 •  Ambient temperature:                                                                         a corrosion inhibitor, it is
                                                    -20°C - +60°C                                5.    Rinsing            Abundant rinsing (at least   recommended to rinse the
                                                                                                                           1 min).
                                                                                                                                                  instruments just before the
                                                    (-4°F - 140°F)                                                                                autoclaving.
                                                 •  Relative humidity:
        Conditions for transport and storage                                                                                                      Dry on a single use non- weaved
                                                    10% - 90%,                                                                                   cloth, or with a drying machine or
                                                    non-condensing                                                                                filtered compressed air.
                                                 •  Operating altitude:                                                                          Defects include:
                                                    106 kPa to 19 kPa                                                                             - deformation of the plastic;
                                                                                                                                                  - corrosion;
                                                 See Appendix 1 (page 158) and/                                                                   - discoloration of the plastic.
        EMC Tables
                                                 or Appendix 2 (page 165)                         6.    Inspection         Inspect devices and sort out
                                                                                                                           those with defects.    Dirty instruments must be
                                                                                                                                                  cleaned and disinfected again.
                                                                                                                                                  Maintenance is not required.
                                                                                                                                                  Do not use instrument lubricant.