Page 342 - CHHA Binder 2.3.20
P. 342
4/11/2019
Dressing Change—PICC, Tunneled Catheter,
Implanted Port*
9
Dressing Change—PICC, Tunneled Catheter, Implanted Port*
Transparent dressing change once a week or as needed for
excessive drainage or excessive perspiration (use occlusive gauze
dressing in place of transparent dressing).
Gauze dressing must be changed more frequently (every 3 days) and
as needed.
Wash hands.
Don sterile gloves.
Utilize sterile technique.
Clean site antisepsis with chlorhexidine.
Clean skin for 30 seconds using back and forth motion and apply
pressure to create friction that will remove skin bacteria.
Allow skin to dry.
Apply transparent dressing over central line catheter site or over non-
coring needle (implanted port).
10
5