Page 343 - CHHA Binder 2.3.20
P. 343

4/11/2019










                              Central Line

                                             Do                            Don’t

                               •  Scrub using Chloroprep (chlorhexidine/alcohol) with back   •  Blot,  fan or blow on the site to speed drying.
                                  and forth motion for 30 seconds and let dry 2 minutes.
                                  Cleanse at least 1 to 1.5 inches on all sides of port or   •  Use Chloroprep on children 2 months of age or younger.
                                  catheter exit site.
                                                                •  Use Chloroprep if patient allergic to chlorhexidine.
                               •  Use 70% alcohol followed by povidone iodine or povidone
                                  alone if Chloroprep cannot be used. Cleanse from center
                                  outward using circular motion .
                               •  Ensure saline and heparin syringes are in sterile package.  •  Place non-sterile syringes on the sterile field.
                               •  Use the transparent semi-permeable dressing of choice.  •  Use gauze under transparent dressing unless severe
                                                                   diaphoresis or drainage (expect some drainage after
                                                                   insertion).
                                                                •  Use gauze dressings unless copious drainage, or
                                                                   diaphoresis.
                               •  Don mask.
                               •  Have patient turn away from the site.
                               •  Measure the length of external catheter from exit at SOC
                                  and with each dressing change.
                               •  Measure the arm circumference 10 cm above PICC catheter
                                  exit site at SOC and with each dressing change.
                                                                                               11










                            Needleless Connector Change




                              Wash hands
                              Don clean gloves.
                              Utilize aseptic no touch technique throughout procedure.
                              Attach 10 mL syringe containing 0.9% NaCl to cap and flush the
                                connector until drops of saline are noted at end of cap. Remove
                                syringe.
                              Place connector aside.
                              Cleanse area at junction of catheter and connector with 70% alcohol
                                swab vigorously for 15—30 seconds.
                              Remove old connector and cleanse end with alcohol wipe.  Allow to
                                dry.
                              Attach new connector.



                                                                                               12







                                                                                                                     6