                     System bus    1: RD+/TD+
                   Input              Output  2: RD--/TD--                      Block diagram of an output
                                   3: TD--/RD--
                                   4: TD+/RD+
                                   5: GND                           Digital Output                     Supply
                                   Housing: Shield                  X1 ... X4
                        M12 B coded
                                                                    M12                                 M12

                                                                                        Output 0 ... 7
                  Digital Outputs X1 ... X4  1: 24 V
                  (two outputs/connector)  3: 0 V U
                                        A
                                                                                                     10 nF  10 nF
                                                                                               Logic
                    5       5                                                          Diagnostics 0 ... 7
                                   5: Shield
                                                                        270 pF
                        M12 A coded
                                   4: Output A
                                   2: Output B
                                   Housing: Shield                   5
                                                                                            Output  Error
                       Supply      1: 24 V U                                                 0 ... 7  F  Module
                    Input               Output  2: 24 V U LS                                             mount
                                   3: 0 V U  A
                                   4: 0 V U LS
                                        A
                        M12 A coded



           Technical Data                                       Technical Data
           Information on actuator selection:                   Isolation:                                          6
            Front-end cycle time 90% (hardware)  max. 0,5 μs      Channel – Channel       No
            Edge steepness          T ON/OFF : typ. < 0,2 μs      U LS , U A , system bus  500 VDC each
            Front-end jitter/skew (output)  < 0,2 μs            Configurable functions:
            Protection against reverse voltages  ≤ 0.5 A          Inversion (per channel)  On/off
            Type of load            Inductive, resistive loads and lamps  Substitute value strategy (per channel)  Switch substitute value/hold last value
            Switching frequency     Inductive load upon request   Substitute value (per channel)  0/1
                                    Resistive load upon request   Manual mode (per channel)  On/off
                                    Lamp load upon request        Manual mode value (per channel)  0/1
            Type of protective circuit  External protection (e.g., recovery diodes)  Online simulation (per channel)  Lock/Unlock; simulation value: 0/1;
           Operating state influence on output:                                           diagnostics
            PLC CPU stop            Acc. to substitute value strategy  I/O diagnostics:
            Fieldbus disruption     Acc. to substitute value strategy  I/O diagnostics (per channel)  Overtemperature, actuators
            S-bus (system bus) disruption  0 V status             I/O diagnostics (per module)  Undervoltage (U LS  + U A )
            Supply voltage under rated voltage                  Process image:
            tolerance               0 V status                    Process data width      1-byte data + status
            Interruption of supply voltage  0 V status          LED indicators:
            Output operation        Non-latching                  SB: System bus status   LED (green/red/orange)
            Overload behavior       Automatic restart             F: Error status         LED (red)
           System bus:                                            0 ... 7: Output signal status  LED (yellow/red)
            Connection type (3)     M12 connectors, B coded, 5 poles,   U LS  + U A : Supply status  LED (green)
                                    shielded                      Indicators              Non-latching
           Standards and approvals:
            Conformity marking      1
            r UL 508













                                                                General Specifications
                                                                Dimensions (mm) W x H x L  50 x 35.7 x 117
                                                                Weight                    270 g