Page 23 - Parker - The Handbook of Hydraulic Filtration
P. 23

Filter Media Selection




              P = Full flow pressure filter (equals               Lubrication Systems
                 one filtration placement)
              R = Full flow return filter (equals one  Component Type  Suggested  Media Efficiency  Number of  Minimum Filter
                 filtration placement)                  Cleanliness Code  Betax >200  Filter Placements*  Placements
              O = Off-line (flow rate 10% of reser-  Ball Bearings         2            1.5       P or R, & O
                 voir volume equals .5 of a filtra-       16/13/11
                 tion placement)                                           2             1          P or R
              * Number of filtration placements in  Roller Bearings        5             2          P & R
                system, more placements are the           17/14/12
                option of the specifier.                                   2            0.5           0
                                          Journal Bearings                 5            1.5       P or R, & O
                                                          18/15/13
                                            Gear Boxes
                                                                           10           2.5        P, R & O




                                                   Hydraulic Systems

               Component Type  System Pressure    Suggested    Media Efficiency   Number of     Minimum Filter
                                               Cleanliness Code   Betax >200   Filter Placements  Placements
                                                                      2               1              P
                                   <1000           17/14/12
                                                                      5               2             P & R
                 Servo Valves
                                  1000-3000        16/13/11           2              1.5            P & O
                                   >3000           16/12/10           2               2             P & R
                                                                      2               1              P
                                   <1000           18/15/13           5              1.5            P & O
                                                                     10              2.5          P, R & O
                 Proportional
                                                                      2               1              P
                    Valves        1000-3000        18/14/12
                                                                      5               2             P & R
                                                                      2              1.5            P & O
                                   >3000           17/14/11
                                                                      5              2.5          P, R & O
                                                                      5               1            P or R
                                   <1000           19/16/14
                                                                     10               2             P & R
                                                                      2              0.5             O
                Variable Volume
                                  1000-3000        18/16/14           5              1.5         P or R, & O
                   Pumps
                                                                     10              2.5          P, R & O
                                                                      2               1            P or R
                                   >3000           18/15/13
                                                                      5               2             P & R
                                                                      5              0.5             O
                                   <1000           20/17/15
                                                                     10              1.5         P or R, & O
                 Vane Pumps
                                                                      5               1            P or R
               Fixed Piston Pumps  1000-3000       19/17/14
                                                                     10               2             P & R
                Cartridge Valves
                                                                      5              1.5         P or R, & O
                                   >3000           19/16/13
                                                                     10              2.5          P, R & O
                                                                     10               1            P or R
                                   <1000           21/18/16
                 Gear Pumps                                          20              2.5          P, R & O
                 Flow Controls    1000-3000        20/17/15          10              1.5         P or R, & O
                   Cylinders                                          5              0.5             O
                                   >3000           20/17/14
                                                                     10              1.5         P or R, & O

                                                                                                                  21
   18   19   20   21   22   23   24   25   26   27   28