Page 10 - Gefran - Product range
P. 10

INVERTER LIFT














          Model               VDL200                            Model                AGL50
          Control mode        Field Oriented Control            Control mode         Space Vector
          Power               4 ... 11kW                        Power                4 - 5,5 - 7.5 kW (5 - 7.5 - 10Hp)
          Voltage             3 x 230-400Vac, -15%+10%, 50Hz    Voltage              3 x 400Vac ... 480Vac, 50/60Hz
          Motor type          Asynchronous
                                                                Motor type           Asynchronous
          Speed control                        (1)
          (Accuracy)          ± 0.01% Motor rated speed         Speed control (Accuracy)  0.5 … 1%
          Analog inputs       1                                 Analog inputs        1
          Analog outputs      no                                Analog outputs       1
          Digital inputs      8 + 1 enable                      Digital inputs       6
          Digital outputs     4 (relay)
                                                                Digital outputs      3 (1 static and 2 relay)
          Overload            Up to 200% In * 10”
                                                                Overload             Up to 170% * In
          Max output frequency  300Hz
                                                                Max output frequency  500Hz
          EMI filter          Integrated (VDL200-F models)
                              (EN 12015; EN 61800-3 category C2 and C3)  EMI filter  Optional
          Choke               DC side choke: external optional  Choke                Optional
                              AC side choke: external optional
          Braking unit        Integrated with external resistor  Braking unit        Integrated with external resistor
          Port for SD card    no                                Port for SD card     no
          Dimensions for room-                                  Dimensions for roomless
          less applications   yes                               applications         yes
          Emergency operation  Optional (UPS single-phase 230V)
                                                                Emergency operation  Optional (with UPS)
          Type of lift        Geared
                                                                Max system speed     1.0 m/s
          Installations       New installation & Retrofitting
                                                                Type of lift         Geared
                              • Speed control
                              • Short floor management          Installations        New installation & Retrofitting
                              • Lift sequence management
                              • Ramp generation
                              • Management of up to 8 Multispeeds                    • 16 multispeeds
                              • Load compensation                                    • 4 multiramps (linear, S-shaped with inde-
                              • Configuration via optional keypad (5 lan-             pendent jerk settings)
                               guages)                                               • Self-tuning of motor  parameters
          Functions           • Configuration via PC (GF_eXpress)                    • Integrated lift sequences
                              • Wizard for commissioning        Functions            • Speed expressed in m/s
                              • Menu for setting electrical and mechanical           • Management of space calculated by the
                               parameters                                             drive, even offline
                              • Programming with linear engineering units            • Management of short floors
                              • DC power supply or emergency single-phase            • Motor contactor control
                               power supply to return to floor with opti-            • Integrated brake control
                               mized consumption                                     • Temperature control for motor and drive.
                              • Conforms to UNI EN 81-1:1998 + A3:2009,
                               article 9.11.3
                                                                Serial communication  RS485  , Modbus RTU
                                                                                         (2)
          Serial communication  RS232  (3)
                                                                Protection degree    IP20
          Protection degree   IP20
          Markings            CE                                Markings             CE, UL and cUL



                            (2) The serial port is used for programming (PC) and control (Modbus communication standard in all drives)
                            (3) The serial port is used for programming (PC).
         10
         10
   5   6   7   8   9   10   11   12   13   14   15