Page 9 - Gefran - Product range
P. 9
DRIVE & MOTION CONTROL
INVERTER LIFT
Model ADL300-2T ADL300-2M ADL300-4 AVRy
Control mode Field Oriented Control Field Oriented Control Field Oriented Control Field Oriented Control
11kW, 20kW and 27kW
Power 5.5 ... 37kW (7.5 ... 50Hp) 1.1 ... 5.5kW (1.5 ... 7.5Hp) 4 ... 75kW (5 ... 100Hp) (with high voltage motors)
or 7.5kW, 14kW and 17kW
(with standard motors)
Voltage 3 x 200Vac, 3 x 230Vac, 50/60Hz 1 x 230Vac; 50/60Hz 3 x 230Vac, 3 x 400Vac, 3 x 480Vac; 50/60Hz 3 x 400Vac,
3 x 460Vac, 50/60Hz
Motor type Asynchronous / Synchronous Asynchronous / Synchronous Asynchronous / Synchronous Synchronous (PM gearless)
Speed control (Accuracy) ± 0,01% Motor rated speed (1) ± 0,01% Motor rated speed (1) ± 0,01% Motor rated speed (1) ± 0,01% Motor rated speed (1)
Analog inputs ADL300B: 0; ADL300A: upon request (*) ADL300B: 0; ADL300A: upon request (*) ADL300B: 0; ADL300A: upon request (*) 2
Analog outputs ADL300B: 0; ADL300A: upon request (*) ADL300B: 0; ADL300A: upon request (*) ADL300B: 0; ADL300A: upon request (*) 2
Digital inputs ADL300B: 8 + 1 enable (*) ADL300B: 8 + 1 enable (*) ADL300B: 8 + 1 enable (*) 6
ADL300A: upon request
ADL300A: upon request
ADL300A: upon request
Digital outputs ADL300B : 4 (relay) ADL300B : 4 (relay) ADL300B : 4 (relay) 4 (2 static and 2 relay)
ADL300A: upon request (*) ADL300A: upon request (*) ADL300A: upon request (*)
Overload Up to 200% In * 10” (up to 11kW) Up to 200% In * 3" Up to 200% In * 10" (up to 22kW) 183% In * 10"
Up to 180% In * 10" (≥ 30kW)
Up to 180% In * 10” (≥ 15kW)
Max output frequency 300Hz 300Hz 300Hz 300Hz
EMI filter Integrated (ADL300.-F models) Optional external Integrated (ADL300.-F models) Integrated (EN 12015)
(EN 12015, EN 61800-3)
(EN 12015, EN 61800-3)
(EN 12015, EN 61800-3)
DC side choke: integrated (≥ 30kW), external DC side choke: integrated (≥ 30kW), external optional
Choke optional on lower sizes no on lower sizes Integrata (EN 12016)
AC side choke: external optional AC side choke: external optional
Braking unit Integrated up to 30kW with external resistor Integrated with external resistor Integrated up to 55kW with external resistor no (Regeneration)
Port for SD card yes yes yes no
Dimensions for roomless
applications yes yes yes yes
Emergency operation Optional (UPS or buffer battery with EMS Optional (UPS or buffer battery with EMS module) Optional (UPS or buffer battery with EMS module) Optional (UPS or buffer battery with EMS module)
module)
Max system speed 4.0 m/s 1.0 m/s 4.0 m/s 3.0 m/s
Type of lift Geared / Gearless Geared / Gearless Geared / Gearless Gearless
Installations New installation & Retrofitting New installation & Retrofitting New installation & Retrofitting New installation & Retrofitting
The ADL300 is available in two configurations: • The ADL300 is certified for the use of a single • Load compensation • Integrated AFE regenerative technology
output contactor, in accordance with UNI EN 81- • DCP3/DCP4 protocol communication • Speed control (EFC Elevator Floor Control function)
(*)
• ADL300A (Advanced): to guarantee 1:1998 + A3:2009, article 9.11.3 • CANopen communication • Lift sequence
maximum programmability, the ADL300A • Safety Certification for a CONTACTORLESS opera- • CANopen –Lift (Cia® 417) communication • Parameters in linear units
is supplied as standard with no I/O or tions: ADL300 is CERTIFIED as EN81-1:1998 + A3
feedback cards, leaving the customer free • STO according to EN61800-5-2-2007 - SIL3 • Configuration via keypad with LEDs • Lift mechanical parameters
to perform the appropriate configura- • Integrated LED keypad • Configuration via optional keypad (5 languages) • Ramp generation.
tion, choosing from an extensive range of • Configuration via PC (GF-eXpress)
options; • Speed control • Wizard for commissioning
Functions • Position control with direct landing at floor (EPC • Menu for setting electrical and mechanical
• ADL300B (Basic) features the following as Elevator Positioning Control) parameters
standard: • Automatic calculation of deceleration point • Programming with linear engineering units
- 8 (Prog. DI) + 1 DI (Enable) + 4 (RO); • Short floor management • DC power supply or emergency single-phase
- channels A+ A-, B+ B-, Z+ Z-, differential • Off-floor stop detection power supply to return to floor with optimized
line drivers, optoisolated; management • Lift sequence management consumption
of loss of encoder signals; encoder signal • Ramp generation
repetition; TTL electrical interface; • External +24VDC power supply
- input for absolute SinCos or Endat / SSI • Management of up to 8 Multispeeds • Regenerative configuration with AFE200 external
modules
encoder.
RS232 , Modbus RTU, DCP3, DCP4, CAN- (2)
(2)
Serial communication open e CANopen Lift DS 417 (ADL300B-...-C RS232 , Modbus RTU, DCP3, DCP4, CANopen and CANopen Lift DS 417 (ADL300B-...-C models). RS485 , Modbus RTU
(2)
Optional: DeviceNet, Profibus DP, CANopen®
models).
Protection degree IP20 IP20 IP20
CE, UL and cUL. Elevator Accessory E365347
Markings certified also evaluated in accordance with CE, UL and cUL CE
ASME A17.5 and CSA B44. Elevator Accessory E365347 certified also evaluated in accordance with ASME A17.5 and CSA B44.