Page 6 - Gefran - Product range
P. 6

INVERTER















          Model                 BDI50                       VDI100                     ADV200                                  ADV200-LC                     ADV200-WA           ADV200-HC           ADP200
          Control mode          V/f, Sensorless (SLV)       V/f, V/f+Encoder, SLV, SV, PMSLV, PMSV  Field Oriented Control     Field Oriented Control        Field Oriented Control                  Vector control with feedback
                                                                                                                                                             1.5kW…1.2MW [2...1600Hp]
                                                                                       0.75kW...1.2MW [1...1600Hp] (-4 models)                               (WA-4)              0.75kW…1.2MW (HC-4)
          Power                 0.4 ... 11 kW (0.5 ... 15 Hp)  0.75 ... 160 kW (1 ... 215 Hp)  75kW...1.65MW [100....2213Hp] (-6 models)  30 ... 400kW (40 ... 500 Hp)  75kW…1.2MW (WA-6)  75kW … 1.65MW (HC-6)  7.5 ... 75kW (10…100 Hp)
                                                                                       18.5kW...1.65MW [25...2213Hp] (-DC models)                            22kW…1.2MW [30...1600Hp]   18.5kW … 1.65MW (HC-DC)
                                                                                                                                                             (WA-DC)
                                                                                       3 x 380…500Vac, 50/60Hz (-4 models)                                   3 x 380…500Vac, 50/60Hz (-4 models)
                                1 x 200~240Vac, 50/60Hz (-2M models)
          Voltage               3 x 200~240Vac, 50/60Hz (-2T models)    3 x 200~240Vac, 50/60Hz (-2T models)  3 x 690Vac, 50/60Hz (-6 models)  3 x 380 ... 500 Vac, 50/60 Hz  3 x 690Vac, 50/60Hz (-6 models)  3 x 230-400-480 Vac, 50/60Hz
                                3 x 380~480Vac, 50/60Hz (-4 models)  3 x 380~480Vac, 50/60Hz (-4 models)  450…750Vdc (-DC-4 models)                          450…750Vdc (-DC-4 models)
                                                                                       600…1120Vdc (-DC-6 models)                                            600…1120Vdc (-DC-6 models)
          Motor type            Asynchronous                Asynchronous / Synchronous  Asynchronous / Synchronous             Asynchronous / Synchronous    Asynchronous                            Synchronous
          Speed control (Accuracy)  ±2% (SLV), ±3% (V/f open-loop)  ±1% (SLV), ±0,1% (SV)  ± 0.01% Motor rated speed   (1)     ± 0.01% Motor rated speed   (1)  ± 30% motor slip rating (V/f   ± 0.01% Motor rated speed   (1)  ±0,01% Motor rated speed
                                                                                                                                                             control)
                                                            ±1,5% (V/f open-loop)
                                                                                                                                                                                                     Control Range: 1:1500
          Analog inputs         2 (Voltage/Current)         2 (Voltage/Current)        2  two-pole (Voltage/Current)           2  two-pole (Voltage/Current)  2  two-pole (Voltage/Current)          3 AI: Voltage/Current + Motor Protection
          Analog outputs        1 (Voltage)                 2 (Voltage/Current)        2  two-pole (1 voltage or current, 1 voltage)  2  two-pole (1 voltage or current, 1 voltage)  2  two-pole (1 voltage or current, 1 voltage)  1 (Voltage/Current)
          Digital inputs        5, NPN/PNP                  8, NPN/PNP                 6 (PNP / NPN)                           6 (PNP / NPN)                 6 (PNP / NPN)                           6 + Enable
          Digital outputs       1 relay                     Sizes 1 = 2  + 1 Relay output  4 (PNP / NPN) , (2 static and 2 relay)  4 (PNP / NPN) , (2 static and 2 relay)  4 (PNP / NPN) , (2 static and 2 relay)  2 + 2 relay
                                                            All other sizes = 1 + 2 Relay outputs
                                                                                       Heavy: Asynchronous=150% * In (1’ every   Heavy Duty: Async.=150% * In (1’ each 5’),
                                                                                                                                                                              (3)
          Overload              150% * In (for 60”)         HD: 150% * In (for 60”), 200% * In (for 2“);   5’); 180% * In (for 0.5 sec), Sync.=160% * In   180% * In (for 0,5”); Sync.=160% * In (1’ each   Light: 110% * In (1’ every 5’)     170% * In (for 60”),
                                                                                       (1’ every 5’); 200% * In (for 3’’)
                                                                                                                               5’), 200% * In (for 3”)
                                                            ND: 120% * In (for 60”)    Light: Asynchronous and Synchronous =   Light Duty: Async. and Sync.=110% * In (1’   Heavy: 150% * In (1’ every 5’); 180% * In (0.5” every 5’)  200% * In (for 3”)
                                                                                       110% * In (1’ every 5’)  (3)            each 5’)  (3)
          Max output frequency  599Hz                       599Hz                      500Hz (depending on drive size)         500Hz (sizes 4300 … 72000),   500Hz (depending on drive size)         300 Hz
                                                                                                                               200Hz (sizes 82500 … 84000)
          EMI filter            Integrated on -F models     Integrated on -F models    Integrated                              Integrated                    Integrated                              Integrated on -F models
                                                                                                                               Integrated choke DC side (up to 200 kW).                              DC side choke: integrated in sizes 30...75kW
          Choke                 Optional                    Built-in on 3ph 400V Class 75-160kW HD  Integrated DC side (up to 132 kW)  External choke inductance mandatory for   Integrated DC side (up to    Integrated DC side (up to   AC side choke: external optional (sizes   7.5...22kW and
                                                                                                                               higher powers.                160 kW)             132 kW)             5S550/5S750 models)
          Braking unit          Built-in on 3ph 400V Class and 3ph 200V   Built-in on 3ph Class 400V 0.75-30kW HD   Integrated (up to 55kW)   Integrated (up to 90kW)   Integrated (up to 75kW)   Integrated (up to 55kW)   Integrated with external resistor (except ADP200-5750
                                                                                                                               Optional external (≥110kW)
                                                                                       External optional (≥75kW)
                                                            and 3ph Class 200V 0.75-18.5kW HD
                                                                                                                                                             External optional (≥90kW)
                                                                                                                                                                                 External optional (≥75kW)
                                Class from 3.7kW to 7.5kW
                                                                                                                                                                                                     model), braking torque 150% max
          Options for integration
          onboard drive         0                           1                          3                                       3                             3                                       2
                                                                                       yes (Motion Drive Programmable Logic
          PLC                   no                          Integrated (Simple PLC Function)  Controller, standard IEC61131-3, 5 lan-  yes (Motion Drive Programmable Logic Con-  yes (Motion Drive Programmable Logic Controller, standard   PLC with advanced IEC61131-3 programming environ-
                                                                                                                                                                                                     ment
                                                                                                                               troller, standard IEC61131-3, 5 languages)
                                                                                                                                                             IEC61131-3, 5 languages)
                                                                                       guages)
          Safety Card           no                          no                         yes (models ADV200-...-SI)              yes (models ADV200-LC-...-SI)  yes (models ADV200-...-SI)             no
                                                                                                                               • Dissipation with liquid, water, or oil via an   • Application Macro for   • Full management of the   • Self-tuning rotational and stand still of speed-cur-
                                                            • Auto-tuning,             (3)                                      innovative cooling system.    HVAC and Pump manage-  mechanical brake  rent-flux regulators and motor data identification
                                                            • Zero Servo,              • Self-tuning of speed-current-flux     • Excellent corrosion protection with alu-  ment  • Torque proving    • Torque control
                                                            • Torque Control,           regulators and identification of motor   minum cooling pipes and internal separa-  • Energy optimization     • Simplified Start-up menu
                                                                                                                                                                                                                           2
                                                            • Position Control,         data with motor idle or rotating                                     • Direct acquisition by   • Joystick Input  • Motor, Drive and Braking resistor I t thermal
                                • Autotune,                 • Droop,                   • Torque control                         tion of electronics and cooling liquid.  PT100, PT1000, NI1000   • Multispeed & Multiramp  protection
                                • 8 preset speeds,          • Soft-PWM,                • Quick startup menu                    • Revolutionary drive mounting system:   temperature sensors   • Overtravel  • Multispeed function (16 programmable preset)
                                                                                       • Instant overload up to 180%
                                                                                                                                                                                                     • 4 independent programmable Multi-ramp with
                                • Auto-run,                 • Over-Voltage Protection,   • Double overload                      inside electrical panel and with external   (with EXP-IO-SEN-...-ADV   • Hoist Speed up  jerks
                                                                                                                                                              cards)
                                                                                                                                heat-sink.
                                • PID control,              • Dynamic Braking,         • I T thermal protection for motor, drive   • Integrated temperature control function to   • Cascade control of up to   • Low speed zone  • Variable switching frequency
                                                                                        2
                                                                                        and braking resistor
                                • Torque boost,             • “Autocapture” function,   • 16 programmable multispeeds and 4     control an external solenoid for drive and   4 pumps, plus the master   • Anti-Sway  • Motor temperature monitoring
          Functions             • Fault reset,              • Frequency Traversing,     multiramp settings (linear, jerk, inde-  liquid-cooled motor.         device (with EXP-IO-D5R8-  • Anti -Impact  • PID function block for injection molding machine
                                                                                                                                                                                                      application
                                                            • Momentary Power Loss Restart,
                                                                                                                                                              ADV card)
                                • Powerloss ride through,   • PID Control,              pendent and S-shape)                   • Braking resistance can be mounted directly   • 4 integrated timers with   • Wide range of encoder and   • Flow and pressure limit control
                                • DC-brake,                 • Automatic Torque Compensation,   • Motor potentiometer function   on heat-sink (for sizes up to 55 kW).  Real Time Clock  communication cards  • Pressure sensor status control
                                                                                       • Motor auto-capture function
                                                                                                                                                                                                     • Adaptive Feedforward
                                • Mechanical brake control,   • Slip Compensation,     • Droop function                        • Integrated humidity sensor with program-  • Fire and Bypass Mode  • Option “Active Front End”   • Automatic switchover between closed-loop speed
                                                                                                                                                             • Two independent PID con-
                                • AVR function,             • RS-485 Communication,    • Dual motor management                  mable anti condensation function.  trollers with autotuning  available.  and pressure control
                                • Fan control.              • Close Loop Control with encoder,   • PID function (application pre-loaded)                     • Variable and constant                 • Speed and pressure control loops tuning
                                                            • Simple PLC Function,     • Mains loss detection with: controlled                                torque operation                       • Pump Rotation direction identification
                                                                                        stop and/or power optimisation
                                                            • 2 Analog Inputs,         • Variable switching frequency                                        • Tool calculator software              • Multipump convergent and divergent control
                                                            • Torque-Off function,     • Speed feedback from Encoder / Re-                                    for pumps and fans                     • Motor protection through KTy, PTC or klixon.
                                                            • Application Presets       solver through option Hardware                                       • Engineering Units pro-
                                                                                                                                                              gramming
                                                                                            (2)
                                RS485 Modbus RTU / ASCII, BACnet.  RS485 Modbus RTU / ASCII.   RS485   , Modbus RTU.           RS485   , Modbus RTU.         RS485   , Modbus RTU.                        (2)
                                                                                                                                                                  (2)
                                                                                                                                    (2)
          Serial communication  Optional: Profibus, DeviceNet, CANopen,   Optional: Profibus/CANopen/DeviceNet/  Optional: DeviceNet, Profibus DP, CAN-  Optional: DeviceNet, Profibus DP, CANopen®,   Optional: DeviceNet, LonWorks®  , BACNet  , Profibus DP,   RS485   , Modbus RTU
                                                                                                                                                                                 (4)
                                                                                                                                                                                        (4)
                                                                                       open®, GDNet, Ethercat, Ethernet IP,
                                                                                                                                                                                                     CANopen® (-C models)
                                TCP/IP                      TCP-IP                     PROFINET                                GDNet, Ethercat, Ethernet IP, PROFINET  CANopen®, GDNet, Ethercat, Ethernet IP
          Protection degree     IP20                        IP20/NEMA1 sizes 1..5      IP20 (IP00 size 7 and parallel)         IP00 / IP54 (-E54=Version with mounting rear panel   IP20 (IP00 size 7 and parallel)  IP20
                                                            IP00 sizes 6-7 (opt. NEMA 1 kit)
                                                                                                                               heat sink with IP54 protection rating)
          Markings              CE, cULus                   CE, cULus                  CE, UL and cUL                          CE, UL and cULus              CE, UL and cUL                          CE
                         SLV (vector control open loop), SV (vector control closed loop), PMSLV (vector control open loop for Permanent Magnet Motor),
                        PMSV (vector control closed loop for Permanent Magnet Motor).
         6 6
   1   2   3   4   5   6   7   8   9   10   11