Page 6 - Gefran - Product range
P. 6
INVERTER
Model BDI50 VDI100 ADV200 ADV200-LC ADV200-WA ADV200-HC ADP200
Control mode V/f, Sensorless (SLV) V/f, V/f+Encoder, SLV, SV, PMSLV, PMSV Field Oriented Control Field Oriented Control Field Oriented Control Vector control with feedback
1.5kW…1.2MW [2...1600Hp]
0.75kW...1.2MW [1...1600Hp] (-4 models) (WA-4) 0.75kW…1.2MW (HC-4)
Power 0.4 ... 11 kW (0.5 ... 15 Hp) 0.75 ... 160 kW (1 ... 215 Hp) 75kW...1.65MW [100....2213Hp] (-6 models) 30 ... 400kW (40 ... 500 Hp) 75kW…1.2MW (WA-6) 75kW … 1.65MW (HC-6) 7.5 ... 75kW (10…100 Hp)
18.5kW...1.65MW [25...2213Hp] (-DC models) 22kW…1.2MW [30...1600Hp] 18.5kW … 1.65MW (HC-DC)
(WA-DC)
3 x 380…500Vac, 50/60Hz (-4 models) 3 x 380…500Vac, 50/60Hz (-4 models)
1 x 200~240Vac, 50/60Hz (-2M models)
Voltage 3 x 200~240Vac, 50/60Hz (-2T models) 3 x 200~240Vac, 50/60Hz (-2T models) 3 x 690Vac, 50/60Hz (-6 models) 3 x 380 ... 500 Vac, 50/60 Hz 3 x 690Vac, 50/60Hz (-6 models) 3 x 230-400-480 Vac, 50/60Hz
3 x 380~480Vac, 50/60Hz (-4 models) 3 x 380~480Vac, 50/60Hz (-4 models) 450…750Vdc (-DC-4 models) 450…750Vdc (-DC-4 models)
600…1120Vdc (-DC-6 models) 600…1120Vdc (-DC-6 models)
Motor type Asynchronous Asynchronous / Synchronous Asynchronous / Synchronous Asynchronous / Synchronous Asynchronous Synchronous
Speed control (Accuracy) ±2% (SLV), ±3% (V/f open-loop) ±1% (SLV), ±0,1% (SV) ± 0.01% Motor rated speed (1) ± 0.01% Motor rated speed (1) ± 30% motor slip rating (V/f ± 0.01% Motor rated speed (1) ±0,01% Motor rated speed
control)
±1,5% (V/f open-loop)
Control Range: 1:1500
Analog inputs 2 (Voltage/Current) 2 (Voltage/Current) 2 two-pole (Voltage/Current) 2 two-pole (Voltage/Current) 2 two-pole (Voltage/Current) 3 AI: Voltage/Current + Motor Protection
Analog outputs 1 (Voltage) 2 (Voltage/Current) 2 two-pole (1 voltage or current, 1 voltage) 2 two-pole (1 voltage or current, 1 voltage) 2 two-pole (1 voltage or current, 1 voltage) 1 (Voltage/Current)
Digital inputs 5, NPN/PNP 8, NPN/PNP 6 (PNP / NPN) 6 (PNP / NPN) 6 (PNP / NPN) 6 + Enable
Digital outputs 1 relay Sizes 1 = 2 + 1 Relay output 4 (PNP / NPN) , (2 static and 2 relay) 4 (PNP / NPN) , (2 static and 2 relay) 4 (PNP / NPN) , (2 static and 2 relay) 2 + 2 relay
All other sizes = 1 + 2 Relay outputs
Heavy: Asynchronous=150% * In (1’ every Heavy Duty: Async.=150% * In (1’ each 5’),
(3)
Overload 150% * In (for 60”) HD: 150% * In (for 60”), 200% * In (for 2“); 5’); 180% * In (for 0.5 sec), Sync.=160% * In 180% * In (for 0,5”); Sync.=160% * In (1’ each Light: 110% * In (1’ every 5’) 170% * In (for 60”),
(1’ every 5’); 200% * In (for 3’’)
5’), 200% * In (for 3”)
ND: 120% * In (for 60”) Light: Asynchronous and Synchronous = Light Duty: Async. and Sync.=110% * In (1’ Heavy: 150% * In (1’ every 5’); 180% * In (0.5” every 5’) 200% * In (for 3”)
110% * In (1’ every 5’) (3) each 5’) (3)
Max output frequency 599Hz 599Hz 500Hz (depending on drive size) 500Hz (sizes 4300 … 72000), 500Hz (depending on drive size) 300 Hz
200Hz (sizes 82500 … 84000)
EMI filter Integrated on -F models Integrated on -F models Integrated Integrated Integrated Integrated on -F models
Integrated choke DC side (up to 200 kW). DC side choke: integrated in sizes 30...75kW
Choke Optional Built-in on 3ph 400V Class 75-160kW HD Integrated DC side (up to 132 kW) External choke inductance mandatory for Integrated DC side (up to Integrated DC side (up to AC side choke: external optional (sizes 7.5...22kW and
higher powers. 160 kW) 132 kW) 5S550/5S750 models)
Braking unit Built-in on 3ph 400V Class and 3ph 200V Built-in on 3ph Class 400V 0.75-30kW HD Integrated (up to 55kW) Integrated (up to 90kW) Integrated (up to 75kW) Integrated (up to 55kW) Integrated with external resistor (except ADP200-5750
Optional external (≥110kW)
External optional (≥75kW)
and 3ph Class 200V 0.75-18.5kW HD
External optional (≥90kW)
External optional (≥75kW)
Class from 3.7kW to 7.5kW
model), braking torque 150% max
Options for integration
onboard drive 0 1 3 3 3 2
yes (Motion Drive Programmable Logic
PLC no Integrated (Simple PLC Function) Controller, standard IEC61131-3, 5 lan- yes (Motion Drive Programmable Logic Con- yes (Motion Drive Programmable Logic Controller, standard PLC with advanced IEC61131-3 programming environ-
ment
troller, standard IEC61131-3, 5 languages)
IEC61131-3, 5 languages)
guages)
Safety Card no no yes (models ADV200-...-SI) yes (models ADV200-LC-...-SI) yes (models ADV200-...-SI) no
• Dissipation with liquid, water, or oil via an • Application Macro for • Full management of the • Self-tuning rotational and stand still of speed-cur-
• Auto-tuning, (3) innovative cooling system. HVAC and Pump manage- mechanical brake rent-flux regulators and motor data identification
• Zero Servo, • Self-tuning of speed-current-flux • Excellent corrosion protection with alu- ment • Torque proving • Torque control
• Torque Control, regulators and identification of motor minum cooling pipes and internal separa- • Energy optimization • Simplified Start-up menu
2
• Position Control, data with motor idle or rotating • Direct acquisition by • Joystick Input • Motor, Drive and Braking resistor I t thermal
• Autotune, • Droop, • Torque control tion of electronics and cooling liquid. PT100, PT1000, NI1000 • Multispeed & Multiramp protection
• 8 preset speeds, • Soft-PWM, • Quick startup menu • Revolutionary drive mounting system: temperature sensors • Overtravel • Multispeed function (16 programmable preset)
• Instant overload up to 180%
• 4 independent programmable Multi-ramp with
• Auto-run, • Over-Voltage Protection, • Double overload inside electrical panel and with external (with EXP-IO-SEN-...-ADV • Hoist Speed up jerks
cards)
heat-sink.
• PID control, • Dynamic Braking, • I T thermal protection for motor, drive • Integrated temperature control function to • Cascade control of up to • Low speed zone • Variable switching frequency
2
and braking resistor
• Torque boost, • “Autocapture” function, • 16 programmable multispeeds and 4 control an external solenoid for drive and 4 pumps, plus the master • Anti-Sway • Motor temperature monitoring
Functions • Fault reset, • Frequency Traversing, multiramp settings (linear, jerk, inde- liquid-cooled motor. device (with EXP-IO-D5R8- • Anti -Impact • PID function block for injection molding machine
application
• Momentary Power Loss Restart,
ADV card)
• Powerloss ride through, • PID Control, pendent and S-shape) • Braking resistance can be mounted directly • 4 integrated timers with • Wide range of encoder and • Flow and pressure limit control
• DC-brake, • Automatic Torque Compensation, • Motor potentiometer function on heat-sink (for sizes up to 55 kW). Real Time Clock communication cards • Pressure sensor status control
• Motor auto-capture function
• Adaptive Feedforward
• Mechanical brake control, • Slip Compensation, • Droop function • Integrated humidity sensor with program- • Fire and Bypass Mode • Option “Active Front End” • Automatic switchover between closed-loop speed
• Two independent PID con-
• AVR function, • RS-485 Communication, • Dual motor management mable anti condensation function. trollers with autotuning available. and pressure control
• Fan control. • Close Loop Control with encoder, • PID function (application pre-loaded) • Variable and constant • Speed and pressure control loops tuning
• Simple PLC Function, • Mains loss detection with: controlled torque operation • Pump Rotation direction identification
stop and/or power optimisation
• 2 Analog Inputs, • Variable switching frequency • Tool calculator software • Multipump convergent and divergent control
• Torque-Off function, • Speed feedback from Encoder / Re- for pumps and fans • Motor protection through KTy, PTC or klixon.
• Application Presets solver through option Hardware • Engineering Units pro-
gramming
(2)
RS485 Modbus RTU / ASCII, BACnet. RS485 Modbus RTU / ASCII. RS485 , Modbus RTU. RS485 , Modbus RTU. RS485 , Modbus RTU. (2)
(2)
(2)
Serial communication Optional: Profibus, DeviceNet, CANopen, Optional: Profibus/CANopen/DeviceNet/ Optional: DeviceNet, Profibus DP, CAN- Optional: DeviceNet, Profibus DP, CANopen®, Optional: DeviceNet, LonWorks® , BACNet , Profibus DP, RS485 , Modbus RTU
(4)
(4)
open®, GDNet, Ethercat, Ethernet IP,
CANopen® (-C models)
TCP/IP TCP-IP PROFINET GDNet, Ethercat, Ethernet IP, PROFINET CANopen®, GDNet, Ethercat, Ethernet IP
Protection degree IP20 IP20/NEMA1 sizes 1..5 IP20 (IP00 size 7 and parallel) IP00 / IP54 (-E54=Version with mounting rear panel IP20 (IP00 size 7 and parallel) IP20
IP00 sizes 6-7 (opt. NEMA 1 kit)
heat sink with IP54 protection rating)
Markings CE, cULus CE, cULus CE, UL and cUL CE, UL and cULus CE, UL and cUL CE
SLV (vector control open loop), SV (vector control closed loop), PMSLV (vector control open loop for Permanent Magnet Motor),
PMSV (vector control closed loop for Permanent Magnet Motor).
6 6