Page 11 - Gefran - Product range
P. 11

DRIVE & MOTION CONTROL



       SERVODRIVE













                                                                                           Regenerative Power Supply
                           AXV300 multi-drive rack                  Power Supply Module
        Model                                    Module                                    Module
                           system                                   AXV300-SM              AXV300-SR-…
                                                                    3-phase                3-phase
                                                  Rated input voltage  400Vac ±10%,        400Vac ±10%,
                2
        Overload I t       slow : 150%  In x 60 sec                 50/60Hz                50/60Hz
                           fast: 200% In x 0,5 sec
                                                  Rated output voltage  from 20 to 230A    from 4.5 to 200A
        Overload IxT       200% In x 10 sec       Output peak current  from 40 to 345A     from 13.5 to 320A


                            MDPlc programming in IEC
                            61131-3 (on the AXV300-CU
        Functions           module): the MDPlc environment   Rated power  from 11 to 122kW  from 2.7 to 120kW
                            is a tool for developing high-level
                            application architectures.

        Operating temperature  0 … +40°C;         Peak power        from 22 to 183kW       -
                           +40°C…+50°C with derating
        Protection degree  IP21                   Switching frequency  -                   -

                                                  External power supply
        Installation position  Pollution degree 2 or lower          24 Vdc                 24 Vdc
                                                  (aux.)
                                                  Performance       -                      -
                           Max 200 metres above sea level;
        Altitude           up to 1000 m with no reduction in
                           current                Vdc bus voltage   565 Vdc                625 Vdc
                                                  Standard I/O      -                      -
        Atmospheric pressure  [kPa] 86 to 106
                           (class 3K3 according to EN50178)
                                                  I/O expansion     -                      -

        Climate            IEC 68-2 Part 2 and 3  Encoder expansion  -                     -

        Isolation distance  EN 50178, UL508C
        Vibration          IEC68-2 Part 6

        Interference immunity  IEC801 Part 2, 3 and 4

        EMC compatibility  EN61800-3

        Safety             STO EN61800-5-2

        Certification      CE
   6   7   8   9   10   11   12   13   14   15   16