Page 81 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 81
Gefran Spa - Drive & Motion Control Unit • www.gefran.com 81
5.2 General Characteristics
Power supply: 3 x 400Vac -15% … 480Vac +10%, Options
50/60Hz ±5% ADV200 - 4
Input choke
Power ratings: from 0,37kW to 22kW Output choke
Max output voltage: 0,94 x Vin
Braking resistors
Output frequency: 500Hz
I/O expansion card: EXP_D6A1R1_ADV80
Asynchronous motors control mode:
Profibus interface: SBI_PDP_ADV80
• Open-loop V/f and V/f with feedback ADV200-DC
CANopen ®/DeviceNet interfaces (incorporated in the
Overload: ADV80-….-C version)
• 150% In for 60 seconds every 5 minutes according to EMC filter for external mounting.
IEC146-1-1 Class 2
GF-eXpress programming software
Standard protection rating IP20 ADV200 - 6
Conformity
Reference resolution: Digital = 0.1 Hz
Analog input = 10-bit + sign General: EN 61800-1, IEC 143-1-1
Analog output = 8 bit Vibration: EN 60068-2-6, test Fc.
Immunity/Emissions: EN61800-3 (with the use of dedicated
filters)
Fieldbus management ADV100
Interfacing with the most commonly-used fieldbus systems:
® Environmental conditions
Ambient temperature: -10 ...40°C,
+40°C…+50°C with derating
Altitude: Max 2000 m.(up to 1000 m with- ADV80
out derating).
CANopen ® and DeviceNet interfaces incorporated in the
ADV80-….-C version.
Markings
Complies with the EEC directive AFE200
Standard supply configuration concerning low voltage equipment.
Regulation:
Complies with directives for the
• Integrated programming keypad American and Canadian market
(sizes 3 only).
• 2 differential analog inputs ±10 V (or current)
• 2 analog outputs (voltage or current) FFE200
• 5 digital inputs (PNP/NPN)
• 2 digital outputs:1 static and 1 relay (PNP/NPN)
• RS485 serial line (Modbus protocol)
SMB200
Power:
• Integrated dynamic braking module.
PROGRAM.
APPENDIX