14 Tests and Testing Procedures per IEC/EN Standards (continued)
586
Electrical Tests
All WAGO products meet requirements for the following electrical tests:
• Temperature-Rise Test to IEC/EN 60947-7-1
The Temperature Rise Test examines the clamping point, including surrounding insulation, at rated current, over-current and short-
circuit current levels.
Unless otherwise specified in the related equipment specification, e.g., by specifying the nominal currents of the equipment, termi-
nal blocks and connectors are tested with current loads as specified in the respective construction specification.
For rail-mounted terminal blocks according to IEC 60947-7-1/EN 60947-7-1/VDE 0611, Part 1, or terminal blocks according to
IEC 60998-1/EN 60998-1/ VDE 0613, Part 1, the temperature rise must not exceed 45 Kelvin.
Voltage drop
measuring point Temperature
measurement
≤ 10 mm
mV
≤ 10 mm
Voltage drop
measuring point
Test arrangement: “Temperature Rise Test”
Rated Cross- Test Current per Conductor Size Test Current per
Section IEC/EN IEC/EN
60947-7-1 60998-1 60947-7-1
Table 4 Table 5 Table 5
mm² A A AWG/kcmil A
0.2 4 4 24 4
0.34 5 5 22 6
0.5 6 6 20 8
0.75 9 9 18 10
1 13.5 13.5 -
1.5 17.5 17.5 16 16
2.5 24 24 14 22
4 32 32 12 29
6 41 41 10 38
10 57 57 8 50
16 76 76 6 67
25 101 101 4 90
35 125 125 2 121
- 1 139
50 150 1/0 162
70 192 2/0 185
95 232 3/0 217
- 4/0 242
120 269 250 kcmil 271
150 309 300 kcmil 309
185 353 350 kcmil 353
240 415 500 kcmil 415
300 520 600 kcmil 520