Page 16 - Manual LEF
P. 16

3.  Close the exhaust opening, if possible.
                                              4.  Shut off the cooling air supply for the turbine.

                                              5.  Position  the  fire  extinguisher  and  spray  the  extinguishing
                                                 agent into the intake port.

                                              6.  Do not open the housing.
                                          Please  not  that filter materials  are  also flammable  and  that they
                                          will develop toxic gases and vapours if they catch fire.
                                          Our  liability  and  warranty  is  expressly  excluded  in  case  of
                                           fire.
                       Remaining risk

                  Accident Prevention –  All  moving  parts  (fan,  motor)  are  covered  by  securely  mounted
                             Mechanics  protection  equipment.  The  cover  can  only  be  removed  with  the
                                          help of tools.
                                          Remaining Risk:
                                           -  Serious injuries may occur if safety covers are removed while
                                              the device is still running.

                                          -  If  the  cover  of  the  filter  chamber  is  opened  or  closed
                                              incautiously bruises and injuries may occur. The cover has to
                                              be handled with the necessary caution.
                  Accident Prevention –  All  energized  parts  of  the  device  are  either  isolated  against
                                Electrics  touching  or  covered  by  securely  mounted  protection  equipment,
                                          which can only be removed with the help of tools. The appliance
                                          complies with protection class I according to EN 60 335.
                                          Remaining Risk:
                                           -  If safety covers are removed while the device is still running
                                              or  not  unplugged,  serious  injuries  may  occur  resulting  from
                                              electrical stroke.
                                          -  If liquids are spilled over the device in the area of the electric
                                              components while the device is still running or not unplugged,
                                              serious injuries may occur resulting from electrical stroke.
                  Accident Prevention –  Only  filters  suitable  for  the  device  may  be  used.  Do  not  run  the
                              Pollutants  appliance without or with damaged filters.
                                          Remaining Risk:
                                           -  If damaged or unsuitable filters are used, serious dangers to
                                              health may occur.
                  Accident Prevention –  Unit  ACD  TD4  and  its  spare  parts  must  be  disposed  of  in
                               Disposal   accordance with your local recycling and waste regulations.
                                          Remaining Risk:
                                           -  If  unit  is  not  disposed  in  accordance  with  your  regulations,
                                              serious dangers to health and environment may occur.

          page 14                                                                        ACD TD - issue 09/2017
   11   12   13   14   15   16   17   18   19   20   21