Page 53 - SIM Guide to annual assessment_v2.0_Dec 2021
P. 53
Grating and Checker Plates
CORRECT INSTALLATIONS
INCLUDES:
• Correct position and installation of grating:
- Bearing bars at span direction
- Banding on the bearing bars edges
- Cross bars at the upper part
• Support length of the gratings must be ≥ 25 mm
• Installation tolerances are respected
• New installations must meet or exceed StDC
(Standard Design Criteria) requirements.
GOOD PRACTICE:
• Consult manufacturer’s installation manual and applicable standards
Bearing bars pointing at wrong direction
Missing banding on bearing bars edges
Placing the steel grill upside down
53