Silo





         MATERIAL FEEDING / EXTRACTION SYSTEM




           Mechanical equipment


             INCLUDES:
             ▪   Checking of Condition of reclaim system (manual and/or pneumatic gate

                 operation, flow control gates, air slide system, cleanliness,...)
             ▪   Equipment  operated/maintained according to supplier's instructions


             GOOD PRACTICE:
             ▪   Obstructions shall be removed and buildups cleaned on a feeder or discharger.
             ▪   Preventive maintenance for mechanical components such as a feeder, vibrating

                 discharger, or discharge gate.
             ▪   Discharge gate position shall be fully open or fully closed.
































             REMARKS:
             ▪   A reparation or replacement of a component / full equipment can affect the silo’s
                 operation.
             ▪   Inspection of mechanical equipment of a silo should be done as part of routine
                 maintenance
             ▪   Silo extraction system  including inverted cone and multiple aerial extraction have a

                 significant impact on the eccentricity of internal loads caused by the different
                 material flow patterns.



             NOTES: